Heating Cost Calculator
See what one kWh of useful heat costs with each fuel, what a heater or boiler costs to run, and what a gas bill comes to. You type the prices from your bill and the values of your own heater: none is built in.
Enter your values
Check these values
Your values are worked out in this browser. They are not sent to a server.
Your result will show here
Fill in the values, then choose Calculate.
Your result
How it was worked out
How to use this calculator
- Choose what you want to work out. Compare heating fuels is the first option.
- Add one row for each fuel. Type the price for one unit of fuel, the energy in one unit, and the efficiency of the heater.
- The unit of fuel is the one your price is for: a kWh, a litre, a gallon, a therm, a kilogram or a ton. Pick the unit for the energy column above the rows.
- If you know the heat your home needs in a year, type it to see the fuel and the cost for a year.
- Choose Calculate. Try an example fills the empty boxes with example values, so that you can see how an option works.
What each option does
- Compare heating fuels: the cost of one kWh and of one million BTU of useful heat for each fuel, with a table and a chart, and the yearly cost for a heat demand.
- Running cost of a heater or boiler: from its power, the hours it runs and the price of its fuel. It also shows the fuel used in an hour.
- Gas bill from meter readings or units: turns cubic metres or hundreds of cubic feet into kWh with the calorific value on your bill, or uses a factor such as therms for each CCF, then adds up the bill.
The formulas
- Cost of one kWh of fuel = price for one unit ÷ energy in one unit.
- Cost of one kWh of heat = cost of one kWh of fuel ÷ efficiency. A boiler with 90% efficiency gives 0.9 kWh of heat for each kWh of fuel. A heat pump with a COP of 3 gives 3 kWh, so its efficiency is 300%.
- Fuel for a year = heat needed ÷ (energy in one unit × efficiency). Cost for a year = fuel × price.
- Running cost: energy used = input power × average load × hours. If the label gives the heat output, input power = heat output ÷ efficiency.
- Gas in kWh = volume in m³ × volume correction factor × calorific value in MJ/m³ ÷ 3.6. One hundred cubic feet is 2.8316846592 m³.
- Bill = gas charge + fixed charges + standing charge × days, then tax on that sum.
Worked examples
Compare. Gas costs 0.08 for one kWh and the boiler has an efficiency of 90%: one kWh of heat costs 0.08 ÷ 0.9 = 0.0889. Electricity costs 0.30 for one kWh. In an electric heater (100%) one kWh of heat costs 0.30. In a heat pump with a COP of 3 (300%) it costs 0.30 ÷ 3 = 0.10. For a home that needs 12,000 kWh of heat a year, that is 1,066.67 with gas, 1,200.00 with the heat pump and 3,600.00 with the electric heater.
Running cost. A boiler with an input of 24 kW runs 6 hours a day at full power: 144 kWh a day. At 0.08 for one kWh, a day costs 11.52, and 180 heating days cost 2,073.60.
Gas bill. The meter moved from 4,820 to 4,905, which is 85 m³. With a correction factor of 1.02264 and a calorific value of 39.5 MJ/m³, that is 85 × 1.02264 × 39.5 ÷ 3.6 = 953.75 kWh. At 0.07 for one kWh the gas charge is 66.76.
Where to find your figures
- Price for one unit of fuel: your bill, your tariff sheet or the price list of your supplier.
- Energy in one unit of fuel: your supplier or the data sheet of the fuel. The list Typical energy in one unit of fuel fills in common values as a start: they differ by product, so check them.
- Efficiency or COP: the label or the data sheet of your heater. A seasonal figure is better than a figure for one test point.
- Calorific value and volume correction factor: printed on a gas bill that is charged in kWh.
- Heat needed each year: an energy certificate, a heat loss calculation, or last year's fuel use × energy in one unit × efficiency.
- The values that Try an example fills in are for trying the tool. They are not current prices and not the values of any real heater.
Limits you should know
- No price, tariff, calorific value or efficiency is built in, and the tool cannot look up the price of a supplier.
- The comparison looks at fuel only. Standing charges, service, the price of a new heater and its life are not counted.
- The efficiency of a real heater changes with the weather and with how it is used. A heat pump has a lower COP on cold days.
- The running cost uses your own hours and average load. A heater with a thermostat does not run at full power all the time.
- A timed gas rate test at the meter is work for a qualified gas engineer. It is not part of this tool.
- Many bills round the cubic feet factor to 2.83. This tool uses 2.8316846592, so its kWh can be about 0.06% above such a bill.
- Money totals are rounded once, at the end, to 2 decimal places, and a half is rounded away from zero. Costs for one kWh are shown to 4 decimal places.
- The costs are estimates from the figures you type. They are not a quote from a supplier.