Works on this device
Sheet Metal Bending Calculator
Work out how long the flat sheet must be before you bend it. Find the bend allowance and the bend deduction from the thickness, the inside radius, the angle and the K-factor, the flat length of a part with many bends, and your own K-factor from a test bend.
Enter your values
Check these values
Your values are worked out in this browser. They are not sent to a server.
Your result will show here
Fill in the values, then choose Calculate.
Your result
How it was worked out
How to use this calculator
- Choose the bend allowance and deduction, the flat length of a part, the K-factor from a test bend, a bend chart, or the smallest radius.
- Type the thickness of the sheet and the inside radius of the bend. Measure the sheet, or take the thickness of its gauge from your supplier's gauge table.
- Type the angle, and say whether it is the bend angle (90° for an L) or the angle left between the flanges.
- Type the K-factor. If you do not know it, bend a test piece and use the K-factor calculation.
- For a part with several bends, type each flange and the bend after it, in order. Choose Calculate.
The formulas
- Bend allowance: BA = θ × (R + K × T), with θ the bend angle in radians, R the inside radius, T the thickness and K the K-factor. It is the length of the neutral line in the bend.
- Outside setback: OSSB = tan(θ ÷ 2) × (R + T). Inside setback: ISSB = tan(θ ÷ 2) × R.
- Bend deduction: BD = 2 × OSSB − BA.
- Flat length: with outside sizes, Σ flanges − Σ BD; with inside sizes, Σ flanges − Σ (2 × ISSB − BA); with the straight flats only, Σ flats + Σ BA.
- K-factor from a test piece: BA = Lf − A − B + 2 × OSSB, then K = (BA ÷ θ − R) ÷ T. The Y-factor is K × π ÷ 2.
- Smallest radius (estimate): R ÷ T = 50 ÷ r − 1, with r the reduction of area in a tensile test in percent (Kalpakjian).
Worked example
A 2 mm sheet is bent 90° over a 2 mm inside radius with K = 0.44. BA = (π ÷ 2) × (2 + 0.44 × 2) = 4.524 mm. OSSB = tan 45° × (2 + 2) = 4 mm, so BD = 2 × 4 − 4.524 = 3.476 mm.
A U channel with outside sizes 50, 30 and 50 mm has two such bends: the flat blank is 130 − 2 × 3.476 = 123.048 mm.
A test piece cut 96.5 mm long and bent to two outside flanges of 50 mm gives BA = 96.5 − 100 + 8 = 4.5 mm, so K = (4.5 ÷ 1.5708 − 2) ÷ 2 = 0.432. The K-factor of 0.44 is an example for trying the tool.
Limits you should know
- The K-factor is an empirical figure. It changes with the material, the ratio R ÷ T, the tooling and the bending method. Test bends on your own machine give the most reliable sizes.
- Sheet metal gauge tables (gauge number to thickness) are not built in: gauges differ for steel, galvanized steel, stainless steel and aluminium, and between standards. Type the thickness from your supplier's table.
- The smallest radius is a rough estimate. The rolling direction, the edges of the blank, the temper and the tools change it; the data sheet of the material decides.
- Hems and bends near 180°, springback and the force of the press brake are not worked out.
- For roof rafter angles, use the Roofing Calculator. For a stair or handrail angle, use the Stair Calculator.