Calculates on this device. File exports run online.
Low Pass Filter Calculator
Choose the kind of low-pass filter. Type two of its values to get the third, the cut-off frequency, the gain and phase at any frequency, and for second-order filters the Q and the −3 dB point.
Enter your values
Check these values
Your values are worked out in this browser. They are not sent to a server.
Your result will show here
Fill in the values, then choose Calculate.
Your result
How it was worked out
How to use the calculator
- Choose the filter: RC, RL, LC, Sallen-Key, the Butterworth order or the digital one-pole filter.
- Choose what you want to find, and type the other values with their units.
- Press Calculate. For RC and RL filters, add a frequency to see the gain and phase there.
- For a sharper filter, use Butterworth order and response, then the box below for a full design with a Bode plot and circuit values.
The formulas
- RC: fc = 1 ÷ (2π R C). RL: fc = R ÷ (2π L). At fc the output is 3.01 dB down and 45° behind; above it, it falls by 20 dB per decade.
- LC into a load R: f0 = 1 ÷ (2π √(L C)), Q = R √(C ÷ L); second order, 40 dB per decade.
- Unity-gain Sallen-Key: f0 = 1 ÷ (2π √(R1 R2 C1 C2)), Q = √(R1 R2 C1 C2) ÷ (C2 (R1 + R2)).
- Butterworth order n: |H|² = 1 ÷ (1 + (f ÷ fc)^(2n)).
- Digital one-pole: y[n] = y[n−1] + α (x[n] − y[n−1]) with α = 1 − e^(−2π fc ÷ fs).
Worked example
R = 10 kΩ and C = 100 nF: fc = 1 ÷ (2π × 10,000 × 0.0000001) = 159.15 Hz. At 5 kHz the gain is 0.0318 (−29.9 dB) and the phase −88.2°.
A Butterworth filter that may lose 3 dB up to 1 kHz and must lose 40 dB from 3 kHz needs order 5 (the formula gives 4.19).
Limits you should know
- Parts are ideal: no source resistance, no load (except the LC load R), no winding resistance, an ideal op-amp. Real parts have tolerances.
- Microstrip, stepped-impedance and other RF (distributed) filters and multiple-feedback active filters are not designed here.