Toolvito

Works on this device

Reynolds Number Calculator

The Reynolds number tells you whether a flow is smooth (laminar) or mixed (turbulent). Work it out for a pipe, a duct of any shape, an open channel, a flat plate or a particle.

Enter your values

The Reynolds number of a flow in a round pipe, a duct of any shape or an open channel, and its flow regime.

Your values

998.2 kg/m³ is water at about 20 °C, an example. It is needed with a dynamic viscosity or a mass flow. Fill in an example from the menu above.

1.002 mPa·s is water at about 20 °C, an example. 1 mPa·s is 1 cP.

Your values are worked out in this browser. They are not sent to a server.

Your result will show here

Fill in the values, then choose Calculate.

How to use this calculator

  1. Choose the geometry: Pipe, duct or channel, Flat plate, or Particle, drop or sphere. Velocity, flow or pipe size for a Reynolds number turns the formula round.
  2. For a pipe or duct, choose the shape and enter its sizes. Give the flow as a mean velocity, a volume flow or a mass flow.
  3. Enter the density and the viscosity of the fluid, as a dynamic viscosity (mPa·s, the same as cP) or a kinematic viscosity (mm²/s, the same as cSt). The menu above the fields fills in rounded examples for water and air.
  4. Choose Calculate. The result shows the Reynolds number, the flow regime and the working.

The formula

  • Re = ρ × v × L ÷ μ = v × L ÷ ν, with ρ the density, v the speed, μ the dynamic viscosity, ν = μ ÷ ρ the kinematic viscosity and L a length that depends on the geometry.
  • Pipe, duct or channel: L is the hydraulic diameter D_h = 4A ÷ P (flow area ÷ wetted perimeter, times 4). For a round pipe flowing full, D_h is the inside diameter; for a rectangular duct D_h = 2ab ÷ (a + b); for an annulus D_h = D_outer − d_inner.
  • Round pipe from a flow: Re = 4Q ÷ (π × D × ν) = 4ṁ ÷ (π × D × μ).
  • Flat plate: L is the distance x from the leading edge, Re_x = U × x ÷ ν.
  • Particle or sphere: L is its diameter and v its speed relative to the fluid.

Laminar or turbulent: the usual boundaries

These boundaries are conventions. They depend on the geometry and on how smooth and calm the flow is, so they are not laws.

Usual flow regime boundaries by geometry
Geometry Laminar Changing Turbulent
Pipe or closed duct (Re with D_h) below 2,300 2,300 to 4,000 4,000 and more
Open channel (Re with R = A ÷ P) below about 500 about 500 to 2,000 above about 2,000
Flat plate (Re_x) below about 500,000 about 300,000 to 3,000,000 above that
Sphere (Re_p) Stokes flow below about 1 intermediate 1 to 1,000 Newton range 1,000 to 200,000

Worked examples

Water at 20 °C (998.2 kg/m³, 1.002 mPa·s) flows at 10 L/s through a pipe with a 100 mm bore. The velocity is 1.273 m/s and Re = 4 × 0.01 ÷ (π × 0.1 × 0.000001004) = 126,841: turbulent. The Pipe Flow Calculator shows the same number for that pipe.

The same water at 1 m/s in that pipe gives Re = 99,621. It would stay laminar below about 0.0231 m/s, where Re = 2,300.

Air at 20 °C (1.204 kg/m³, 0.01813 mPa·s) at 10 m/s along a plate: 0.5 m from its front edge, Re_x = 332,046, so the boundary layer is still laminar by the usual 500,000 rule.

Limits you should know

  • The fluid properties must be those at the temperature of the flow. The menu values are rounded examples.
  • The regime boundaries are a guide. A smooth, quiet pipe can stay laminar far above 2,300; a rough or disturbed one turns turbulent earlier.
  • For friction factors and pressure drop, use the Darcy Weisbach Calculator and the Pipe Flow Calculator. For open channels, the Froude number is on the Froude Number Calculator.
  • The results are arithmetic for the values you type. This is not professional advice.

Related tools