Works on this device
Reynolds Number Calculator
The Reynolds number tells you whether a flow is smooth (laminar) or mixed (turbulent). Work it out for a pipe, a duct of any shape, an open channel, a flat plate or a particle.
Enter your values
Check these values
Your values are worked out in this browser. They are not sent to a server.
Your result will show here
Fill in the values, then choose Calculate.
Your result
How it was worked out
How to use this calculator
- Choose the geometry: Pipe, duct or channel, Flat plate, or Particle, drop or sphere. Velocity, flow or pipe size for a Reynolds number turns the formula round.
- For a pipe or duct, choose the shape and enter its sizes. Give the flow as a mean velocity, a volume flow or a mass flow.
- Enter the density and the viscosity of the fluid, as a dynamic viscosity (mPa·s, the same as cP) or a kinematic viscosity (mm²/s, the same as cSt). The menu above the fields fills in rounded examples for water and air.
- Choose Calculate. The result shows the Reynolds number, the flow regime and the working.
The formula
- Re = ρ × v × L ÷ μ = v × L ÷ ν, with ρ the density, v the speed, μ the dynamic viscosity, ν = μ ÷ ρ the kinematic viscosity and L a length that depends on the geometry.
- Pipe, duct or channel: L is the hydraulic diameter D_h = 4A ÷ P (flow area ÷ wetted perimeter, times 4). For a round pipe flowing full, D_h is the inside diameter; for a rectangular duct D_h = 2ab ÷ (a + b); for an annulus D_h = D_outer − d_inner.
- Round pipe from a flow: Re = 4Q ÷ (π × D × ν) = 4ṁ ÷ (π × D × μ).
- Flat plate: L is the distance x from the leading edge, Re_x = U × x ÷ ν.
- Particle or sphere: L is its diameter and v its speed relative to the fluid.
Laminar or turbulent: the usual boundaries
These boundaries are conventions. They depend on the geometry and on how smooth and calm the flow is, so they are not laws.
| Geometry | Laminar | Changing | Turbulent |
|---|---|---|---|
| Pipe or closed duct (Re with D_h) | below 2,300 | 2,300 to 4,000 | 4,000 and more |
| Open channel (Re with R = A ÷ P) | below about 500 | about 500 to 2,000 | above about 2,000 |
| Flat plate (Re_x) | below about 500,000 | about 300,000 to 3,000,000 | above that |
| Sphere (Re_p) | Stokes flow below about 1 | intermediate 1 to 1,000 | Newton range 1,000 to 200,000 |
Worked examples
Water at 20 °C (998.2 kg/m³, 1.002 mPa·s) flows at 10 L/s through a pipe with a 100 mm bore. The velocity is 1.273 m/s and Re = 4 × 0.01 ÷ (π × 0.1 × 0.000001004) = 126,841: turbulent. The Pipe Flow Calculator shows the same number for that pipe.
The same water at 1 m/s in that pipe gives Re = 99,621. It would stay laminar below about 0.0231 m/s, where Re = 2,300.
Air at 20 °C (1.204 kg/m³, 0.01813 mPa·s) at 10 m/s along a plate: 0.5 m from its front edge, Re_x = 332,046, so the boundary layer is still laminar by the usual 500,000 rule.
Limits you should know
- The fluid properties must be those at the temperature of the flow. The menu values are rounded examples.
- The regime boundaries are a guide. A smooth, quiet pipe can stay laminar far above 2,300; a rough or disturbed one turns turbulent earlier.
- For friction factors and pressure drop, use the Darcy Weisbach Calculator and the Pipe Flow Calculator. For open channels, the Froude number is on the Froude Number Calculator.
- The results are arithmetic for the values you type. This is not professional advice.