Works on this device
Coupling Torque Calculator
Work out the design torque to choose a coupling, from the torque or the power and speed of the drive and the service factor in the coupling maker's table. Check the torque that a keyed hub or the fitted bolts of a flange coupling can carry with your allowable stresses.
Enter your values
Check these values
Your values are worked out in this browser. They are not sent to a server.
Your result will show here
Fill in the values, then choose Calculate.
Your result
How it was worked out
How to use this calculator
- Choose the design torque, a keyed hub, or a bolted flange coupling.
- For the design torque, enter the torque, or the power and the speed, and the service factor from the table of your coupling maker. Add the rated torque of a coupling size to compare.
- For a key or bolts, enter the sizes and your allowable shear stress and bearing pressure from your design code or handbook.
- Choose Calculate. The result says which check decides.
The formulas
b, L and t are the width, length and bearing height of the key, d the shaft diameter, n the number of bolts, d_b their diameter, D_b the bolt circle and t_f the thickness of the thinner flange.
- Design torque: T_d = T_n × K, with T_n = P ÷ ω (9549.3 × kW ÷ rpm in N·m) and K the service factor.
- Key in shear: T = τ_a × b × L × d ÷ 2. Key in bearing: T = p_a × t × L × d ÷ 2.
- Fitted bolts in shear: T = n × τ_a × (π × d_b² ÷ 4) × D_b ÷ 2.
- Flange bearing on the bolts: T = n × p_a × d_b × t_f × D_b ÷ 2.
Worked example
A 30 kW motor at 1,470 rpm drives a pump. The nominal torque is 9549.3 × 30 ÷ 1,470 = 194.9 N·m. With a service factor of 1.75 the design torque is 341.0 N·m, which is 85.3% of a coupling rated at 400 N·m.
A 14 mm key, 70 mm long, in a 50 mm shaft with 4.5 mm bearing on the hub: at 60 MPa in shear it carries 1,470 N·m, and at 100 MPa bearing pressure 787.5 N·m, so the bearing pressure decides at 787.5 N·m.
Six fitted bolts of 12 mm on a 160 mm circle with 20 mm flanges: at 80 MPa in shear they carry 4,343 N·m. The service factor and the allowable stresses are examples for trying the tool, not design values.
Limits you should know
- These results are ideal arithmetic, not a design approval and not professional advice. The catalogue of the coupling maker, your design code and your safety factors decide.
- Service factors, ratings and allowable stresses are your figures. Each coupling maker has its own service factor table; none is built in.
- Friction-grip (preloaded) bolted joints, shrink and taper fits, splines, fatigue and the keyway in the shaft are not worked out here.
- For the torque on the shaft and its stress, use the Shaft Torque Calculator. For the stress in a keyway, use the Keyway Stress Calculator. For the twist of a flexible coupling, use the Torsional Stiffness Calculator.