Toolvito

Processed online by Toolvito

Biological Sequence Analyzer

Paste a sequence or choose a FASTA, GenBank or other sequence file. Work out GC content, molecular weight and other facts, turn DNA into RNA or into its reverse complement, translate it into protein, find open reading frames, or calculate the melting temperature of a primer.

Choose what to do

Task
Sequence facts (GC content, molecular weight)

Or drop files here. FA, FASTA, FAS, FNA, FFN, FAA, FRN, MFA, SEQ, TXT, FQ, FASTQ, GB, GBK, GENBANK, GBFF, EMBL, EMB, ALN, CLUSTAL, CLW, PHY, PHYLIP, STO, STK, STH, CSV, TSV or TAB, up to 20 files, 100 MB each at most.

    More options

    When you run a task here, Toolvito receives the information you submit for processing. Download the result within one hour after the job finishes. Choose Delete files now to request earlier removal. The hourly cleanup normally removes files within one to two hours after completion.

    How to analyse a sequence

    1. Choose a task: Sequence facts, DNA and RNA, Translate or Melting temperature.
    2. Paste the sequence (plain letters or FASTA with ">" names), or choose one or more files.
    3. Press the button. The result is shown on the page; download the table (CSV) or the sequences (FASTA).

    What the sequence facts are

    • GC content in % of the bases, and the GC and AT skew ((G−C)/(G+C) and (A−T)/(A+T)).
    • Molecular weight of DNA and RNA from the elemental formulas of the nucleotides with the IUPAC standard atomic weights: single and double strand, with a 5'-OH end (as made by oligo synthesis) or a 5'-phosphate, linear or circular. Sequences with N or other ambiguous letters get no weight.
    • Protein molecular weight (average and monoisotopic) from the amino acid residue masses Expasy publishes, plus one water.
    • Extinction coefficient at 280 nm as in Expasy ProtParam (Trp 5500, Tyr 1490, cystine 125 M⁻¹cm⁻¹, Pace et al. 1995), the aliphatic index (Ikai 1980) and GRAVY (the mean Kyte & Doolittle hydropathy).

    Melting temperature (Tm)

    • Nearest-neighbour (default): the thermodynamic tables of Allawi & SantaLucia (1997) or SantaLucia & Hicks (2004) for a perfectly matched DNA duplex. The primer concentration matters: give the oligo concentration (and the template concentration if it is not small).
    • Salt: give Na⁺, K⁺, Tris, Mg²⁺ and dNTPs in mM. Other ions are turned into a sodium equivalent (von Ahsen et al. 2001); the Owczarzy (2008) correction handles Mg²⁺ and dNTPs itself.
    • GC formula and the Wallace rule (2 °C per A or T, 4 °C per G or C, for oligos up to about 14 bases) are also listed.
    • The same formulas give the same numbers as Biopython's MeltingTemp module. Calculators of polymerase suppliers (for example for Q5 or Phusion) use their own buffers and corrections, so their numbers can differ by a few degrees; LNA and other modified bases are not modelled. A Tm is an estimate: test the annealing temperature.

    Translation and open reading frames

    • All 27 NCBI genetic codes (standard, vertebrate mitochondrial, bacterial and plastid, yeast and others), one frame or all six.
    • An open reading frame (ORF) here runs from a start codon to the next stop codon in the same frame, on both strands. Choose the shortest length in amino acids.
    • Protein to DNA writes each amino acid with IUPAC codes for its codons (for example GCN for alanine), because the real codons cannot be known.

    Privacy

    Your sequences and files are sent to the Toolvito server to be worked on. Download the result within one hour after the job finishes. Choose Delete files now to request earlier removal. The hourly cleanup normally removes files within one to two hours after completion.

    Related tools