Works on this device
Magnetic Permeability Calculator
Magnetic permeability tells how strongly a material carries a magnetic field. Work out the permeability μ and the relative permeability μr from a measured B and H, convert between μr, μ and the susceptibility χ, find the flux density in a core, or find μr of a ring core from its inductance. No material values are built in: you type the value for your material.
Enter your values
Check these values
Your values are worked out in this browser. They are not sent to a server.
Your result will show here
Fill in the values, then choose Calculate.
Your result
How it was worked out
How to use this calculator
- Choose what you want: μ from B and H, a conversion between μr, μ and χ, the field in a core, or μr of a ring core from its inductance.
- For B and H, type the measured flux density B and the field strength H, or the turns, current and mean length of the winding (then H = N I ÷ l).
- Where the tool needs μr of a material, type the value from its data sheet for your field. Try an example fills in a value only for trying the tool.
- Pick the unit of μ in the answer: µH/m, mH/m or H/m.
- Choose Calculate. The answer shows μr, μ and χ with the working.
The permeability formulas
- Permeability: μ = B ÷ H, in henries per metre (H/m, the same as N/A²). B is the flux density in teslas and H the field strength in amperes per metre.
- Relative permeability: μr = μ ÷ μ0, with μ0 = 1.25663706127 × 10^-6 H/m (CODATA 2022). It has no unit: 1 for a vacuum, very close to 1 for air, water, copper and aluminium.
- Susceptibility: χ = μr − 1. It is a little below 0 for a diamagnetic material, a little above 0 for a paramagnetic one, and large for iron, steels and ferrites.
- Field strength of a winding: H = N × I ÷ l, for a ring core or a core that fills a long solenoid, with l the mean length of the path in the core.
- Flux density in a core: B = μ0 × μr × N × I ÷ l, while the core stays below saturation.
- Ring core from its inductance: L = μ0 μr N² Ae ÷ le, so μr = L le ÷ (μ0 N² Ae). With the inductance factor AL (L = AL × N²), μr = AL le ÷ (μ0 Ae).
Worked examples
From B and H. A sample carries B = 1.2 T at H = 800 A/m. μ = 1.2 ÷ 800 = 0.0015 H/m, so μr = 0.0015 ÷ (1.2566 × 10^-6) = 1,194, about 1,200, and χ is about 1,200 too.
From the winding. 200 turns with 0.50 A on a ring core with a mean path of 20 cm give H = 200 × 0.50 ÷ 0.20 = 500 A/m. With B = 1.2 T, μr = 1.2 ÷ (1.2566 × 10^-6 × 500) = 1,910, about 1,900.
Field in a core. 400 turns with 0.50 A over 20 cm give H = 1,000 A/m. With μr = 1,000 the core carries B = 1.2566 × 10^-6 × 1,000 × 1,000 = 1.26 T, about 1.3 T, against about 1.3 mT with no core.
Ring core. 20 turns on a ring core with le = 10 cm and Ae = 0.50 cm² measure 0.50 mH. μr = 0.00050 × 0.10 ÷ (1.2566 × 10^-6 × 20² × 0.000050) = 1,989, about 2,000.
Limits you should know
- The μr of iron, steels and ferrites is not a fixed number. It changes with the field, falls as the material nears saturation, and depends on how it was magnetised before (hysteresis). Each result holds at one field only.
- Above the saturation flux density of the core (on its data sheet) the real B is much lower than B = μ0 μr N I ÷ l.
- H = N I ÷ l holds for a closed ring or a core that fills a long coil. An air gap or a short rod lowers the field in the material.
- The example values are only for trying the tool and are not data for any material.
- Answers are shown to the significant figures of your least precise input.
- For the field of coils see the Solenoid Magnetic Field Calculator and the Magnetic Field Calculator, which also has a core with an air gap. For the inductance of a coil see the Inductor & Coil Calculator.