Toolvito

Works on this device

Greenhouse Calculator

Find the floor area, the area to cover and the air volume of a greenhouse with a ridge roof, a lean-to or a round-arch tunnel. Then work out the film, panels or shade cloth to buy, how many benches and plants fit, the fan flow for the air changes you choose, and a rough estimate of the heat it loses on a cold night.

Enter your values

The floor, the surfaces to cover and the air inside a greenhouse with a ridge roof, a lean-to or a round-arch tunnel.

Your values

You can also type feet and inches, such as 12 ft 6 in, or a fraction such as 10 1/2.

For a lean-to: from the wall to the front. For a tunnel: the span at the ground.

Your values are worked out in this browser. They are not sent to a server.

Your result will show here

Fill in the values, then choose Calculate.

How to use this calculator

  1. Choose what you want to work out. Floor area, cover area and air volume is the first choice.
  2. Choose the shape and type its sizes. A length can be typed as feet and inches, such as 9 ft 6 in, or in metres.
  3. Figures for your materials and crop start empty: the extra for overlaps, the plant spacing, the air changes and the heat loss factor. Try an example fills in examples only.
  4. Choose Calculate. You can change the unit of a result, copy it, print it or download it as a CSV file.

The formulas

  • Ridge roof: end wall = width × wall height + width × (ridge − wall height) ÷ 2. Roof slope = √((width ÷ 2)² + (ridge − wall height)²). Roof = 2 × length × slope.
  • Lean-to: end wall = width × (height at the wall + height at the front) ÷ 2. Roof slope = √(width² + (wall height − front height)²). The building wall is not covered.
  • Round-arch tunnel: the arch is part of a circle through the two feet and the top. Radius = (span² ÷ 4 + height²) ÷ (2 × height); angle = 4 × atan(2 × height ÷ span); arch length = radius × angle; end area = radius² ÷ 2 × (angle − sin angle).
  • Air volume = end area × length. Air flow = air volume × air changes each hour ÷ 60 minutes.
  • Benches across the floor = (width + aisle) ÷ (bench + aisle), rounded down, when the aisles are only between the benches.
  • Heat loss = area of the cover × heat loss factor (U-value) × (inside − outside temperature). This is a rough estimate.

Worked examples

A ridge-roof house 20 ft long and 10 ft wide, with 6 ft walls and a 9 ft ridge: the floor is 200 sq ft. Each end is 10 × 6 + 10 × 3 ÷ 2 = 75 sq ft, so the air volume is 1,500 cu ft. The roof slope is √(5² + 3²) = 5.831 ft, so the roof is 233.24 sq ft. With 240 sq ft of side walls and 150 sq ft of ends, the cover is 623.24 sq ft.

A tunnel 20 ft long with a span of 10 ft and an arch 5 ft high is a half circle: each arch is 5 × π = 15.71 ft long. One sheet of film with 2 ft extra at each side and 4 ft at each end is 19.71 ft × 28 ft.

Benches: on a floor of 20 × 10 ft, benches 3 ft wide with 2 ft aisles between them and 2 ft at each end: 2 benches 16 ft long, 96 sq ft or 48% of the floor. At a spacing of 6 in in a square grid, 192 pots fit on each bench, 384 in all.

Fans: 1,500 cu ft changed 60 times an hour needs 1,500 cu ft each minute (cfm), so 2 fans of 1,000 cfm.

Heat: the ridge-roof house with a cover at 1.1 BTU/(h·ft²·°F), 60 °F inside and 20 °F outside loses about 623.24 × 1.1 × 40 = 27,422 BTU/h, about 8.04 kW. That is a rough estimate.

The overlap, spacing, air changes and heat loss factor in these examples are examples only, not advice.

Other tools for the same subject

Limits you should know

  • The heating need counts heat lost through the cover only. Air leaks, wind, the ground and a clear night sky add to it; sun and stored heat lower it. It is not professional advice on the size of a heater.
  • No climate data of any place is built in. Use the coldest night you plan for from your own local records.
  • The heat loss factors in the list are rough examples for common covers, not the values of any product. Use the figure of your maker.
  • The tool gives no air change rate, spacing or aisle width as advice.