Works on this device
Rebar Development Length Calculator
The development length is how far a bar must be embedded in concrete to reach its full strength. This page works it out by the named methods of ACI 318-19 and EN 1992-1-1 (Eurocode 2), with the factors you type from your code.
Enter your values
Check these values
Your values are worked out in this browser. They are not sent to a server.
Your result will show here
Fill in the values, then choose Calculate.
Your result
How it was worked out
How to use this calculator
- Choose the method: the general ACI equation, the simplified ACI table, ACI in compression, or the Eurocode 2 anchorage length.
- For ACI, choose the inch-pound or the SI form of the equation. Choose the bar, or type its diameter.
- Type the strengths and every factor (ψ, λ or α) from your code. These boxes start empty: Try an example fills in example values, which are not values for your case.
- Choose Calculate. The working shows the equation with your numbers, and which limit governs.
The methods
- ACI 318-19 25.4.2.4(a): ld = (3/40) × (fy ÷ (λ √f′c)) × (ψt ψe ψs ψg ÷ ((cb + Ktr) ÷ db)) × db in inch-pound units; the SI form of ACI 318M-19 has 1 ÷ 1.1 in place of 3/40. (cb + Ktr) ÷ db is at most 2.5, ψt ψe at most 1.7, √f′c at most 100 psi (8.3 MPa), and ld at least 12 in (300 mm).
- ACI 318-19 Table 25.4.2.3: ld = fy ψt ψe ψg db ÷ (k λ √f′c), with k = 25 or 20 (SI 2.1 or 1.7) when the spacing and cover meet the first row, and 50/3 or 40/3 (SI 1.4 or 1.1) for other cases, for No. 6 and smaller or No. 7 and larger bars.
- ACI 318-19 25.4.9.2 (compression): ldc = the greater of fy ψr db ÷ (50 λ √f′c) and 0.0003 fy ψr db, at least 8 in (SI: 0.24 and 0.043, at least 200 mm).
- EN 1992-1-1:2004 8.4: lb,rqd = (φ ÷ 4)(σsd ÷ fbd), fbd = 2.25 η1 η2 fctd, lbd = α1 α2 α3 α4 α5 lb,rqd with α2 α3 α5 ≥ 0.7, and lbd ≥ lb,min = max(0.3 lb,rqd, 10 φ, 100 mm) in tension (0.6 lb,rqd in compression).
Worked examples
ACI 318-19, inch-pound: a #7 bar (db = 0.875 in), fy = 60,000 psi, f′c = 4,000 psi, all ψ and λ = 1, cb = 2.5 in and Ktr = 0. Then (cb + Ktr) ÷ db = 2.86, limited to 2.5, and ld = 0.075 × 60,000 ÷ 63.25 × (1 ÷ 2.5) × 0.875 = 24.9 in, or 28.5 bar diameters.
The simplified table for the same bar in the first row gives ld = 60,000 ÷ (20 × 63.25) × 0.875 = 41.5 in (47.4 db). In compression, ldc = 60,000 × 0.875 ÷ (50 × 63.25) = 16.6 in.
Eurocode 2: a 20 mm bar at σsd = 434.8 MPa with fbd = 3.0 MPa (fctk,0.05 = 2.0 MPa, γc = 1.5, good bond) has lb,rqd = (20 ÷ 4) × (434.8 ÷ 3.0) = 724.7 mm. With all α = 1, lbd = 724.7 mm, or 36.2 φ. These factors are examples for trying the tool, not values for your case.
Limits you should know
- The tool holds no code factors. Every ψ, λ and α, the bond strength, γc and αct are typed by you from the code and edition in force (and the National Annex for Eurocode 2).
- Straight bars only. Hooked and headed bars, bundled bars, the reduction for excess reinforcement and the special rules for seismic design are not covered.
- For lap splices, use the Rebar Lap Length Calculator. For bar spacing and cover, see the Rebar Spacing Calculator and the Concrete Cover Calculator.
- The engineer of record and the code in force decide the development length. This tool does not check a design. It is not professional advice.