Works on this device
Concrete Cover Calculator
Concrete cover is the clear distance from the surface of the concrete to the nearest bar. Use this page to find where the bars sit, the effective depth d, the depth a member needs, or the nominal cover of Eurocode 2 from the values of your code.
Enter your values
Check these values
Your values are worked out in this browser. They are not sent to a server.
Your result will show here
Fill in the values, then choose Calculate.
Your result
How it was worked out
How to use this calculator
- Choose what you want to work out.
- Type the overall depth and the clear cover from your drawing, and choose the stirrup and the main bar. Bars are listed by ASTM bar number and by metric diameter; you can also type a diameter.
- The cover box starts empty, because the cover comes from your drawing and your code. Try an example fills in example values.
- To compare with the minimum cover of your code, type it in the box for the minimum. The tool holds no code values.
- Choose Calculate. The working shows each step.
The formulas
- Effective depth (one layer): d = h − c − stirrup − bar ÷ 2.
- Two equal layers: d = h − c − stirrup − bar − gap ÷ 2, to the centre of both layers.
- Overall depth for a d: h = d + c + stirrup + bar ÷ 2.
- Cover from a drawing: c = h − d − stirrup − bar ÷ 2.
- Nominal cover, EN 1992-1-1:2004 clause 4.4.1: c_nom = c_min + Δc_dev, with c_min = max{c_min,b; c_min,dur + Δc_dur,γ − Δc_dur,st − Δc_dur,add; 10 mm}.
Worked example
A beam is 500 mm deep with 40 mm clear cover, 10 mm stirrups and 20 mm main bars. The centre of the bars is 40 + 10 + 10 = 60 mm from the surface, so d = 500 − 60 = 440 mm. With two layers of 20 mm bars and a 25 mm gap, d = 500 − 40 − 10 − 20 − 12.5 = 417.5 mm to the centre of both layers.
In inches: a 24 in beam with 1.5 in cover, #4 stirrups (0.5 in) and #8 bars (1.0 in) has d = 24 − 1.5 − 0.5 − 0.5 = 21.5 in.
Eurocode 2 with example values: c_min,b = 20 mm, c_min,dur = 25 mm and Δc_dev = 10 mm give c_min = 25 mm and c_nom = 35 mm. These example values are for trying the tool and are not code values.
Limits you should know
- Minimum cover depends on the code, its edition, the exposure, the member, the bar size and the fire rating. Type it from the code in force; the example values on this page are not code values.
- Bar sizes are nominal diameters. Ribs make a real bar a little larger.
- For how many bars fit and their spacing, use the Rebar Spacing Calculator. For the quantity of bars in a slab, use the Slab Reinforcement Estimator.
- How much area a bag or a cubic yard of concrete covers is a different question: see the Concrete Quantity Calculator.
- The engineer of record and the code in force decide the cover of a real member. This tool does not check a design. It is not professional advice.