Culvert Flow Calculator
Find how high water stands at the inlet of a round or box culvert for a design flow, the flow its barrel carries flowing full, the flow its inlet lets in at a headwater, and the smallest of your sizes that keeps the headwater within a limit.
Enter your values
Check these values
Your values are worked out in this browser. They are not sent to a server.
Your result will show here
Fill in the values, then choose Calculate.
Your result
How it was worked out
How to use this calculator
- Choose what you want to work out. Headwater for a design flow checks both inlet control and outlet control.
- Choose a round pipe or a box, and type its inside size, length and slope.
- Type the coefficients from your design manual: Manning's n, the entrance loss ke, and the orifice and weir coefficients of your inlet. The boxes start empty; Try an example fills in example values that come from no table.
- Type the tailwater depth (0 for a free outfall) and, if you have one, the highest headwater allowed.
- Choose Calculate. The working shows both controls step by step.
The method
- Inlet control, inlet not submerged (weir form): Q = Cw × L × HW^(3/2), with L the span of a box or the diameter of a round pipe.
- Inlet control, inlet submerged (orifice form): Q = Cd × A × √(2g × (HW − D ÷ 2)).
- The tool takes the orifice form when it gives a headwater at or above the top of the opening D, the weir form when it gives one at or below D, and between the two the higher weir value.
- Outlet control, barrel flowing full: HW = H + h_o − L × S, where H = (1 + ke + 2g × n² × L ÷ (k² × R^(4/3))) × V² ÷ (2g) adds the exit loss, the entrance loss and the friction loss, and h_o is the larger of the tailwater and (dc + D) ÷ 2, with dc the critical depth.
- Headwater = the larger of the inlet control and the outlet control headwater.
- Barrel capacity flowing full (Manning): Q = (k ÷ n) × A × R^(2/3) × S^(1/2), with k = 1 in SI units.
Worked example
A round culvert 1.2 m across and 30 m long at 1 % carries 2 m³/s to a free outfall. Take n = 0.012, ke = 0.5, Cd = 0.6 and Cw = 1.7 (SI units) as examples.
Inlet control: the weir form gives HW = (2 ÷ (1.7 × 1.2))^(2/3) = 0.987 m. That is below D = 1.2 m (the orifice form would give 1.043 m, also below D), so the inlet is not submerged and the inlet control headwater is 0.987 m.
Outlet control: A = 1.131 m², V = 1.768 m/s and V² ÷ 2g = 0.1594 m. The friction term is 2g × 0.012² × 30 ÷ 0.3^(4/3) = 0.422, so H = (1 + 0.5 + 0.422) × 0.1594 = 0.306 m. The critical depth is 0.778 m, so h_o = (0.778 + 1.2) ÷ 2 = 0.989 m, and HW = 0.306 + 0.989 − 30 × 0.01 = 0.995 m.
The headwater is 0.995 m, set by outlet control by a small margin. Flowing full, the same barrel carries 4.224 m³/s.
Limits you should know
- This is a simple hand method. A culvert design under FHWA HDS-5 (Hydraulic Design of Highway Culverts) or your agency's manual needs its own inlet control charts or equations, its coefficients for your inlet, and its checks of part-full flow and outlet velocity.
- Manning's n, the entrance loss ke, the coefficients Cd and Cw and the headwater allowed come from the design manual or code in force where the work is done. That code decides; this tool does not give the required values.
- A weir coefficient has units. Choose whether yours is made for SI units or US units; the two differ by a factor of about 1.81.
- The design flow comes from a hydrology method such as the rational method on the Rainfall Intensity Calculator. A storm drain pipe without inlet and outlet losses is on the Storm Drain Capacity Calculator, and the slope of a pipe on the Plumbing Slope Calculator.
- This is arithmetic for the values you type. A culvert must be designed and checked by a qualified engineer. It is not professional advice.