Storm Drain Capacity Calculator
Find how much water a round storm drain or storm sewer carries at its slope, how deep and fast a design flow runs in it, and the pipe size a design flow needs. Type the Manning roughness n and any velocity limits from your drainage manual.
Enter your values
Check these values
Your values are worked out in this browser. They are not sent to a server.
Your result will show here
Fill in the values, then choose Calculate.
Your result
How it was worked out
How to use this calculator
- Choose what you want to work out: the capacity of a pipe, a check of a pipe for a design flow, the flow at a depth, or the pipe size for a flow.
- Type the inside diameter and the slope of the pipe. The slope can be a percentage, inches for each foot, 1 in X and other forms.
- Type Manning's roughness n for your pipe from your drainage manual or the pipe maker. The box starts empty; Try an example fills in example values.
- If your manual sets a smallest or largest velocity, type them to check the pipe against them.
- Choose Calculate. The working shows each step.
The formulas
- Manning equation: V = (k ÷ n) × R^(2/3) × S^(1/2) and Q = V × A, with k = 1 in SI units (1.49 in feet and seconds), R = A ÷ P the hydraulic radius and S the slope as fall ÷ length.
- Pipe flowing full: A = π × D² ÷ 4 and R = D ÷ 4.
- Pipe part full at depth y: θ = 2 × arccos(1 − 2y ÷ D), A = D² × (θ − sin θ) ÷ 8, P = D × θ ÷ 2.
- Normal depth of a design flow: the depth at which the Manning flow equals that flow, found by halving a range of depths.
- Size for a flow: D = (Q × n ÷ (k × c1 × (c1 ÷ c3)^(2/3) × √S))^(3/8), where A = c1 × D² and P = c3 × D at the chosen share of the depth (c1 = π ÷ 4 and c3 = π when full).
Worked example
A concrete pipe with an inside diameter of 450 mm is laid at 1 %. Take n = 0.013 as an example. Flowing full, A = π × 0.45² ÷ 4 = 0.15904 m² and R = 0.45 ÷ 4 = 0.1125 m. V = (1 ÷ 0.013) × 0.1125^(2/3) × 0.01^(1/2) = 1.7926 m/s, so Q = 1.7926 × 0.15904 = 0.2851 m³/s, or 285.1 L/s.
A design flow of 150 L/s in this pipe is 52.6 % of the full capacity. It runs 231.9 mm deep (51.5 % of the diameter) at 1.815 m/s.
For 150 L/s at 1 % with n = 0.013, a pipe flowing full needs an inside diameter of at least 353.7 mm, so of the sizes 300, 375 and 450 mm the 375 mm pipe is the smallest that is large enough.
Limits you should know
- Manning's n, the smallest and largest velocity, the depth a drain may run at and the sizes allowed come from the drainage manual or code in force where the work is done. That code decides; this tool does not give the required values.
- The design flow comes first. The Rainfall Intensity Calculator gives the peak flow of an area by the rational method, and the Runoff Coefficient Calculator gives the weighted C of mixed surfaces.
- The tool takes steady, uniform flow with one n at every depth. Inlets, junctions, bends and a high water level downstream lower the real capacity; a full design checks the hydraulic grade line.
- A round pipe with one n carries most at about 94 % of its depth, a little more than full. Designs do not count on that extra flow.
- Box and other shapes are on the Manning Equation Calculator; culverts with inlet and outlet losses are on the Culvert Flow Calculator.
- This is arithmetic for the values you type. A storm drain must be designed and checked by a qualified engineer. It is not professional advice.