Toolvito

Works on this device

Compressed Air Energy Calculator

Find the power a compressor needs for a flow and a pressure, what compressed air costs in a year, and what a lower pressure or a better compressor saves. The efficiencies, the specific power and the price are your own figures: none is built in.

Enter your values

The power to compress a flow of air to a pressure by an ideal model, the shaft and electrical power with your efficiencies, and the specific power.

Your values

The volume of air taken in each hour or minute, measured at the inlet conditions. 600 m³/h is 10 m³/min.

The pressure that the gauge shows, above the air around it.

With more than one stage, the air is taken to be cooled back to the inlet temperature between the stages, and every stage has the same pressure ratio.

The isentropic or the isothermal efficiency. From the data sheet of your own compressor. No typical value is built in. Type 100 for the ideal power of the model.

From the rating plate of the motor and the data of the drive. Type 100 to see the shaft power.

More options

1.4 for dry air.

The absolute pressure of the air around the compressor or the tank. 1.01325 bar is the standard atmosphere at sea level. It is lower at altitude.

Used only for the temperature of the air after a stage.

Your values are worked out in this browser. They are not sent to a server.

Your result will show here

Fill in the values, then choose Calculate.

How to use this calculator

  1. Choose what you want to work out. Compressor power from flow and pressure is the first option.
  2. Type the flow of free air and the discharge pressure that the gauge shows.
  3. Choose the compression model. Type the efficiency of the compressor against that model and the efficiency of the motor, both from the data sheet. Type 100 for each to see the ideal power.
  4. For the yearly cost, choose Yearly energy and cost of a compressor and type the input power, the hours and your price for one kWh.
  5. Choose Calculate. Try an example fills the empty boxes with example values, so that you can see how an option works.

What each option does

  • Compressor power: the ideal power of the model, the shaft power, the electrical input power and the specific power.
  • Yearly energy and cost: energy loaded and unloaded, the cost, and the cost of 1,000 m³ of air.
  • Savings from a lower discharge pressure: the share of energy saved, by the ratio of the ideal powers at the two pressures.
  • Savings from a compressor with a lower specific power: the same air with less power.
  • Energy stored in a tank: the work that the air in a tank can do when it expands.
  • Air receiver: the time a tank can supply a flow, the tank size for a time, or the flow from a pump-up or leak-down test.

The formulas

  • Pressure ratio r = (gauge pressure + pressure of the air around) ÷ pressure of the air around.
  • Isothermal power = inlet pressure × flow × ln(r). This is the least power that is possible.
  • Adiabatic power with N stages = N × k ÷ (k − 1) × inlet pressure × flow × (r^((k − 1) ÷ (k × N)) − 1), with k = 1.4 for air and cooling to the inlet temperature between the stages.
  • Electrical input power = ideal power ÷ efficiency of the compressor ÷ efficiency of the motor.
  • Specific power = input power ÷ flow, in kW for each m³/min or for each 100 cfm.
  • Energy in a year = input power × hours loaded + input power × share when unloaded × hours unloaded.
  • Tank, isothermal: work = absolute pressure × volume × ln(r). Tank, adiabatic: work = absolute pressure × volume ÷ (k − 1) × (1 − r^(−(k − 1) ÷ k)).
  • Receiver: time = tank volume × (higher pressure − lower pressure) ÷ (flow of free air × pressure of the air around).

Worked examples

Power. A compressor takes in 600 m³/h (10 m³/min) and delivers it at 7 bar gauge. The inlet pressure is 1.01325 bar, so the pressure ratio is 8.01325 ÷ 1.01325 = 7.908. With the adiabatic model and one stage, the ideal power is 47.61 kW. With a compressor efficiency of 75% and a motor efficiency of 93%, the input power is 47.61 ÷ 0.75 ÷ 0.93 = 68.26 kW. That is 6.826 kW for each m³/min.

Yearly cost. An input power of 75 kW for 4,000 loaded hours is 300,000 kWh. At 0.12 for one kWh, that is 36,000.00 a year.

Lower pressure. With the same adiabatic model, going from 7 bar to 6 bar gauge saves 8.38% of the energy. For 300,000 kWh a year at 0.12, that is 25,128 kWh and 3,015.34 a year.

Receiver. A tank of 500 litres falls from 8 bar to 6 bar while the users take 120 m³/h more than the compressor delivers. It can supply that for 0.5 × 200 ÷ (0.03333 × 101.325) = 29.6 seconds.

Where to find your figures

  • Flow of free air, input power, specific power, efficiency: the data sheet of the compressor (often to ISO 1217), or your own measurements.
  • Hours loaded and unloaded: the hour meters of the compressor controller.
  • Electricity price for one kWh: your bill or contract.
  • The values that Try an example fills in are for trying the tool. They are not the data of any real compressor, and not current prices.

Limits you should know

  • The models treat air as an ideal gas. They leave out friction, leaks, pressure drops in filters and dryers, and the humidity of the air.
  • The saving from a lower pressure takes the flow and the efficiency to stay the same. Check first that every user of the air still gets the pressure it needs.
  • A compressor with a variable speed drive, or one at part load, does not draw its loaded power all the time. Use measured energy for those.
  • The cost of leaks is not worked out here.
  • A pressure vessel sets its stored energy free at once if it fails. Tanks must follow the pressure equipment rules of your country.
  • Yearly costs are rounded once to 2 decimal places, and a half is rounded away from zero. A saving is the difference of two rounded costs.
  • The results are estimates for study and for a first look. They do not size a compressor, a pipe or a receiver. For a decision on spending, ask a qualified engineer and use measurements.

Related tools