Works on this device
Motor Energy Savings Calculator
Find the electricity a motor uses, and what you save with a motor of higher efficiency, a lower input power, or a variable speed drive on a fan or pump. You type the efficiencies from the rating plates and your own price: none is built in.
Enter your values
Check these values
Your values are worked out in this browser. They are not sent to a server.
Your result will show here
Fill in the values, then choose Calculate.
Your result
How it was worked out
How to use this calculator
- Choose what you want to work out. Savings from a more efficient motor is the first option.
- Type the rated power from the rating plate, the load on the motor and the running hours in a year.
- Type the efficiency of the motor now and of the new motor, both from the rating plate or the data sheet.
- Type your electricity price for one kWh, and the cost of the change if you want the payback time.
- Choose Calculate. Try an example fills the empty boxes with example values, so that you can see how an option works.
What each option does
- A more efficient motor: the same shaft power with less input power.
- Energy use and cost of a motor: the kWh and the cost for a year, and the part lost in the motor.
- A lower input power: for any change where you know the watts before and after, such as a new fan motor.
- A variable speed drive on a fan or pump: the energy when the machine slows down for part of the year, by the cube law, with a table and a chart.
The formulas
- Input power = rated power × load ÷ efficiency.
- Power saved = rated power × load × (1 ÷ efficiency now − 1 ÷ efficiency of the new motor).
- Energy = input power × running hours. Cost = energy × price for one kWh.
- Cube law for a fan or a pump: power at a speed = power at full speed × (speed ÷ full speed)³. At 80% speed the power is 51.2%.
- Simple payback time = cost of the change ÷ saving each year.
Worked examples
A more efficient motor. A motor of 15 kW runs at 75% load for 4,000 hours a year. The shaft power is 11.25 kW. With an efficiency of 89.5% it draws 12.570 kW, and with 93% it draws 12.097 kW. The saving is 0.473 kW, which is 1,892.2 kWh a year. At 0.12 for one kWh that is 227.07 a year. An extra cost of 1,400 pays back in 6.17 years.
Energy use. The same motor with an efficiency of 91% draws 12.363 kW and uses 49,450.5 kWh a year, which costs 5,934.07.
Variable speed drive. A fan draws 30 kW at full speed. With a drive of 97% efficiency it runs 1,000 hours at 100%, 2,000 hours at 80% and 1,000 hours at 60% speed. Without the drive it uses 30 × 4,000 = 120,000 kWh. With the drive it uses 69,278.4 kWh, so 42.27% is saved.
Where to find your figures
- Rated power and efficiency: the rating plate or the data sheet of each motor. Efficiency classes such as IE2, IE3 or NEMA Premium set a lowest value for each size, which the tool does not hold: type the value of your own motor.
- Load: a measurement of the input power or the current. The motor load calculator turns it into a load share.
- Running hours: an hour meter, the control system or your shift plan.
- Electricity price: your bill or contract.
- The values that Try an example fills in are for trying the tool. They are not the data of any real motor and not current prices.
Limits you should know
- The efficiency of a motor changes with its load. Use the efficiency at the load in use.
- A more efficient motor often turns a little faster. On a fan or a pump, that can take away part of the saving.
- The drive option compares with full speed for all the hours. If a damper or a valve already cuts the flow, the real saving is smaller.
- The cube law holds for fans, and for pumps that work mostly against friction. A pump that lifts water to a height saves less.
- Only the energy is priced. A lower demand charge, a grant and the cost of stopping the machine are not counted.
- Each yearly cost is rounded to 2 decimal places, and a half is rounded away from zero. The saving is the difference of the two rounded costs.
- The saving is an estimate from the figures you type. For a decision on spending, measure the motor and ask a qualified engineer.