Calculates on this device. File exports run online.
Energy Audit Calculator
List your appliances to see where your electricity goes, check your bills for daily use and base load, and compare saving measures by their payback.
Enter your values
Check these values
Your values are worked out in this browser. They are not sent to a server.
Your result will show here
Fill in the values, then choose Calculate.
Your result
How it was worked out
How to do a simple energy audit
- In Energy use of appliances and lights, list what uses electricity, its power in watts and how long it runs. Add your price per kWh to see costs.
- In Energy bills, type the days and energy of each bill for a year. Add the average outdoor temperature if you have it.
- In Savings and payback of measures, list what you could change, the energy it saves and what it costs.
- With temperatures for six or more bills, use the box below for a weather-related baseline of your use.
The formulas
- Energy per year (kWh) = power (W) × how many × hours per day × days per year ÷ 1,000. Standby power counts in the other hours of those days.
- Use per day = energy of a bill ÷ its days. The base load estimate is the lowest use per day × all days: what you use whatever the weather.
- Simple payback (years) = cost of a measure ÷ money it saves per year.
- Weather baseline: change-point models of ASHRAE Guideline 14 relate use per day to the outdoor temperature: a flat base load plus a heating slope below a change point and a cooling slope above one.
Worked example
Ten 9 W LED bulbs for 5 hours a day: 9 × 10 × 5 × 365 ÷ 1,000 = 164.25 kWh a year. With the other appliances of the example the home uses 1,027.75 kWh a year; at 0.15 per kWh that costs 154.16 a year.
Limits you should know
- No prices, tariffs or emission factors are built in: they depend on your supplier, country and year. Type the ones on your bill.
- The power on a label is often the largest draw. Fridges and freezers cycle; use the yearly kWh on their energy label instead (divide by 8.76 for the average watts).
- This is a desk audit. It does not replace a professional energy assessment with measurements.