Works on this device
Weld Strength Calculator
Work out the load that fillet and butt welds can carry, from their throat area and the allowable stress of your code, or the filler strength times the factor of your code. Find the length of weld for a load, and the weld size for a bracket or a tube under a pull, a shear force, bending and twisting together.
Enter your values
Check these values
Your values are worked out in this browser. They are not sent to a server.
Your result will show here
Fill in the values, then choose Calculate.
Your result
How it was worked out
How to use this calculator
- Choose fillet welds, a butt weld, the length of weld needed, or a weld group under combined loads.
- Type the size of the weld (the leg or the throat) and its length, or the shape and sizes of the weld group.
- Type the allowable stress from your code, or the strength of the filler metal and the factor your code gives.
- Choose Calculate. Add a load to check to see the stress and the share of the strength it uses.
The formulas
Line properties for each unit of throat: one weld of length d has Sw = d² ÷ 6 and Jw = d³ ÷ 12; two welds d long and b apart Sw = d² ÷ 3 and Jw = d (3b² + d²) ÷ 6; a rectangle b × d all round Sw = b d + d² ÷ 3 and Jw = (b + d)³ ÷ 6; a circle of diameter d Sw = π d² ÷ 4 and Jw = π d³ ÷ 4.
- Fillet welds: F = τa × a × L, with a the throat (a = 0.70711 z for equal legs at a right angle), L the effective length and τa the allowable shear stress on the throat. Per unit length: τa × a.
- From the filler strength: τa = factor × filler strength, with the factor from your code.
- Butt (groove) weld: F = allowable stress × te × L, with te the thickness of the thinner part for full penetration, or the effective throat of your code for partial penetration.
- Length needed: L = F ÷ (τa × a).
- Weld group, weld treated as a line: at the worst point, across the face P ÷ L + M ÷ Sw, and in the face V ÷ L + T × c ÷ Jw. The resultant f = √(across² + in the face²) needs a throat a = f ÷ τa.
Worked example
A 6 mm fillet weld has a throat of 6 × 0.70711 = 4.243 mm. At an allowable shear stress of 140 MPa it carries 594.0 N on each millimetre, so 200 mm of weld carries 118.8 kN. A load of 60 kN needs 101.0 mm of such weld: 50.5 mm on each side of a plate welded on two sides.
In inch units, a 1/4 in fillet with an allowable of 0.30 × 70 ksi = 21 ksi on the throat carries 3.71 kip on each inch.
A butt weld through a 10 mm plate, 150 mm long, at 150 MPa carries 225 kN. A bracket held by two welds 150 mm long and 100 mm apart, with 20 kN and a bending moment of 2 kN·m, has 66.67 N/mm from the shear and 266.67 N/mm from bending: f = 274.87 N/mm, so it needs a throat of 1.963 mm (a leg of 2.777 mm) at 140 MPa. The allowable stresses here are examples for trying the tool.
Limits you should know
- This is ideal arithmetic for study and planning, not a design approval and not professional advice. Welds must be designed to the welding or structural code that applies (for example AWS D1.1, EN 1993-1-8 or IS 800) and checked by a qualified engineer.
- Allowable stresses, filler strengths and factors are your figures from your code. No code table is built in. For aluminium, the strength of the heat-affected zone often decides; use the figures of your code.
- The whole force on the throat is taken as shear. Codes such as EN 1993-1-8 also have a method that splits the stress into its directions; it is not built in.
- In a weld group the parts in the face are added as if they pointed the same way, which is on the safe side. Fatigue, the base metal next to the weld and the parts themselves are not checked.
- For the size of a fillet weld and its throat and leg, use the Weld Size Calculator. For fillet welds in more depth, see the Fillet Weld Calculator.