Works on this device
Bolt Shear Calculator
Work out the shear stress in bolts or pins that carry a load across a joint, in single or double shear. Choose whether the shear plane cuts the plain shank or the thread. Compare with an allowable shear stress that you type, find the load the bolts can carry, or the pin diameter you need.
Enter your values
Check these values
Your values are worked out in this browser. They are not sent to a server.
Your result will show here
Fill in the values, then choose Calculate.
Your result
How it was worked out
How to use this calculator
- Choose the shear stress for a load, the load the bolts can carry, or the diameter needed.
- Choose where the shear plane passes: the plain shank (or a pin), the thread with its tensile stress area, the thread with its root area, or an area you type.
- Choose single or double shear, and type the number of bolts and the load.
- Type the allowable shear stress from your design code or standard. Choose Calculate.
The formulas
Single shear: the bolt joins two parts that overlap and is cut in one plane. Double shear: the bolt passes through a part held between two others and is cut in two planes, so each plane takes half the load.
- Shear stress: τ = F ÷ (n × m × A), with F the load, n the number of bolts, m the number of shear planes in each bolt and A the area of one bolt in one plane.
- Load the bolts can carry: F = n × m × A × τa, with τa the allowable shear stress.
- Diameter of a pin: A = F ÷ (n × m × τa) and d = √(4 × A ÷ π).
- Areas: shank A = π × d² ÷ 4; thread: the tensile stress area As (ISO 898-1 or ASME B1.1), or the root area π × d3² ÷ 4 with d3 = d − 1.226869 P for an ISO metric thread.
Worked example
One 12 mm shank in single shear carries 20 kN. Its area is π × 12² ÷ 4 = 113.1 mm², so the shear stress is 20,000 N ÷ 113.1 mm² = 176.8 MPa.
Four M16 × 2 bolts in double shear carry 100 kN with the thread in the shear planes. Each plane takes 12.5 kN on the stress area of 156.7 mm², so τ = 79.79 MPa: 53.2% of an allowable of 150 MPa.
For 50 kN on two pins in double shear with an allowable of 100 MPa, each pin needs 125 mm² in each plane: a diameter of at least 12.62 mm. The allowable stresses here are examples for trying the tool, not design values.
Limits you should know
- This is ideal arithmetic for study and planning, not a design approval and not professional advice. The design must follow the code or standard that applies to your connection and be checked by a qualified engineer.
- Allowable stresses are your figures. No bolt grade, code allowable or shear strength table is built in; a code can also reduce the strength when the thread lies in the shear plane.
- The stress is the average shear stress. The load is taken as shared evenly, with no bending of the bolts and no friction between the parts. Slip-critical (friction-grip) joints and loads off the centre of a bolt group are not worked out.
- The bearing of the parts on the bolt, edge distances and the strength of the parts are not checked here.
- For the preload of a bolt, use the Bolt Preload Calculator. For thread sizes and stress areas, use the Screw Thread Calculator. For a whole connection, see the Bolted Connection Calculator.