Toolvito

Calculates on this device. File exports run online.

RL Filter Calculator

Type the resistor and the inductor of an RL filter to get its cut-off frequency, or find the inductor or the resistor for a cut-off. You also get the time constant, the gain, the loss and phase at a frequency, a Bode chart and the step response, with the coil resistance taken into account.

Enter your values

Your values

The DC resistance of the inductor winding; 0 for an ideal coil.

Optional: the loss and phase there.

Your values are worked out in this browser. They are not sent to a server.

Your result will show here

Fill in the values, then choose Calculate.

Filter analysed on the server

Filter analysed on the server

Uses the filter of the result above as its transfer function H(s). The server gives the Bode plot, the pole, the −3 dB point, the step and impulse responses and the gain at fc/2, fc and 2 fc, with CSV and JSON files.

The calculator above works on your device. When you run a task in this section, Toolvito receives the values and result you submit to make the file or run the check. Download the result within one hour after the job finishes. Choose Delete files now to request earlier removal. The hourly cleanup normally removes files within one to two hours after completion.

How to use the RL filter calculator

  1. Choose Low-pass (the inductor in series, the output across R) or High-pass (R in series, the output across the inductor).
  2. Choose what to find and type the other values. Add the coil resistance r if you know it (from the data sheet or an ohmmeter).
  3. Press Calculate. The box under the result analyses the filter on the server and compares the gains.

The formulas

  • Low-pass: H = R ÷ (R + r + jωL), cut-off fc = (R + r) ÷ (2π L), pass-band gain R ÷ (R + r).
  • High-pass: H = (r + jωL) ÷ (R + r + jωL); with an ideal coil fc = R ÷ (2π L).
  • Time constant τ = L ÷ (R + r); a step reaches 63.2 % after τ and 90 % after 2.3 τ.

Worked example

R = 100 Ω and L = 10 mH give fc = 100 ÷ (2π × 0.01) = 1591.5 Hz and τ = 0.1 ms. At 5 kHz the low-pass is 10.36 dB down with a phase of −72.3°.

A coil resistance of 10 Ω raises the low-pass cut-off to 1750.7 Hz and lowers its pass-band gain to 0.909 (−0.83 dB).

Limits you should know

  • A load across the output acts in parallel with R (low-pass) or with the inductor (high-pass): include it. Real inductors also have capacitance between their turns, which matters at high frequencies.
  • Return loss and VSWR (RL in radio work) are in the VSWR and return loss calculator.