Voltage Regulator Heat Calculator

A linear voltage regulator turns the voltage it drops into heat. This tool works out the watts, the junction temperature with or without a heat sink, the heat sink you need, and the largest current for a temperature limit. It also finds the resistors of an adjustable regulator.

Enter your values

How many watts a linear regulator turns into heat, and how hot its junction gets with or without a heat sink.

Your values

The highest input voltage gives the most heat.

The highest air temperature around the regulator, inside the case of the device.

From the data sheet of the regulator, for your package and way of mounting.

From the data sheet of the regulator: the highest operating junction temperature. Many designs stay well below it.

More options

From the data sheet: the quiescent or ground-pin current at your load. It flows from the input to ground inside the regulator.

From the data sheet, at your output current. The input must stay above the output by at least this much.

Your values are worked out in this browser. They are not sent to a server.

Your result will show here

Fill in the values, then choose Calculate.

How to use this calculator

  1. Enter the input voltage, the output voltage and the output current. Use the highest input voltage and the highest current that can happen together.
  2. Enter the highest air temperature around the regulator.
  3. Choose the heat path: no heat sink, or a heat sink. Then type the thermal resistances from the data sheets. These fields start empty, because the tool has no regulator data. Try an example fills in sample values.
  4. Type the highest junction temperature that the data sheet allows.
  5. Choose Calculate. The result shows the heat in watts, the junction temperature and how it compares with the limit.

The formulas

  • Heat = (input voltage − output voltage) × output current + input voltage × ground-pin current.
  • Junction temperature = ambient temperature + heat × thermal resistance, junction to ambient.
  • With a heat sink, the thermal resistance is the sum of three parts: junction to case, case to heat sink, and heat sink to air.
  • Heat sink needed = (junction limit − ambient temperature) ÷ heat − junction to case − case to heat sink. This is the largest value; a smaller number is a better heat sink.
  • Largest output current = ((junction limit − ambient temperature) ÷ thermal resistance − input voltage × ground-pin current) ÷ (input voltage − output voltage).
  • Adjustable regulator: output voltage = reference voltage × (1 + R2 ÷ R1) + adjust-pin current × R2.

Worked example

The thermal values and the temperature limit in this example and in the Try an example button are sample values. Use the values from your own data sheets.

A regulator makes 5 V from 12 V at 0.5 A. Heat = (12 − 5) × 0.5 = 3.5 W. Without a heat sink, at 50 °C/W and 25 °C around it, the junction would rise by 3.5 × 50 = 175 °C to 200 °C. That is above a limit of 125 °C.

With a heat sink of 10 °C/W, 5 °C/W from junction to case and 0.5 °C/W from case to sink, the sum is 15.5 °C/W. The rise is 3.5 × 15.5 = 54.25 °C, so the junction is at 79.25 °C and the heat sink at 60 °C.

The largest heat sink value for the limit of 125 °C is 100 ÷ 3.5 − 5 − 0.5 = 23.07 °C/W. Without a heat sink the same regulator can give 2 ÷ 7 = 0.2857 A.

An adjustable regulator with a reference voltage of 1.25 V and R1 = 240 Ω needs R2 = (5 − 1.25) ÷ (1.25 ÷ 240) = 720 Ω for 5 V.

Limits you should know

  • The result is arithmetic on the values you typed. It is not professional engineering advice. Check a real design against the data sheet of your regulator, and measure the temperature of the finished device.
  • The tool holds no regulator data. The thermal resistances, the temperature limit and the reference voltage are your inputs, and the limits in the data sheet decide. A part that gets too hot fails or can start a fire.
  • The junction-to-ambient value in a data sheet holds for the test board of the maker. Your board, the air flow and warm parts nearby change it.
  • The model is steady heat flow. Short pulses of heat, and the time a heat sink takes to warm up, are not covered.
  • A junction below the limit is not proof of a safe design. A cooler junction gives a longer life, so many designs keep a wide margin.
  • The heat formula is for linear regulators. A switching regulator loses far less, and its loss comes from its efficiency.
  • The tool gives exact resistor values and has no table of standard values.
  • For a Zener diode regulator, use the Zener Resistor Calculator.