In a steady flow, what goes in must come out. The continuity equation turns that into numbers: the flow rate A × v is the same at every section of a pipe, and the flows into a junction equal the flows out.
Enter your values
Check these values
Your values are worked out in this browser. They are not sent to a server.
Your result will show here
Fill in the values, then choose Calculate.
Your result
How it was worked out
How to use this calculator
- Choose what you want to work out: the velocity or size at a second section, a change of density, a junction of several pipes, or a heart valve area.
- Enter the sizes and velocities you know. Pick a unit for each value.
- For a junction, add one row for each pipe. Give a velocity (with the diameter) or a flow for each, and leave one row open: the tool finds its flow.
- Choose Calculate and read the working under the result.
The formulas
- Constant density (a liquid): Q = A1 × v1 = A2 × v2, so v2 = v1 × A1 ÷ A2. For round pipes v2 = v1 × (D1 ÷ D2)².
- Changing density (a gas that is heated, cooled or compressed): ṁ = ρ1 × A1 × v1 = ρ2 × A2 × v2.
- Junction: the sum of the flows in equals the sum of the flows out. A velocity becomes a flow by Q = v × π × D² ÷ 4.
- Heart valve area (echocardiography): AVA = (π × D_LVOT² ÷ 4) × VTI_LVOT ÷ VTI_AV. The same blood volume passes the outflow tract (LVOT) and the valve in one beat. The mitral valve area uses the mitral VTI in the same way.
Worked examples
Water at 1.5 m/s in a 100 mm pipe enters a 50 mm pipe. The area is a quarter, so the velocity is four times larger: 6 m/s. The flow is 11.78 L/s in both pipes.
For 3 m/s after the reducer, the second pipe needs a bore of 100 × √(1.5 ÷ 3) = 70.71 mm.
Air at 1.2 kg/m³ and 1.5 m/s in a 100 mm duct passes into a 50 mm duct where its density is 0.9 kg/m³. The mass flow stays 50.89 kg/h and the velocity becomes 8 m/s.
A 150 mm main at 2 m/s (35.34 L/s) feeds branch A with 15 L/s. Branch B (80 mm) then carries 20.34 L/s at 4.047 m/s.
An LVOT diameter of 2.0 cm, an LVOT VTI of 20 cm and an aortic VTI of 80 cm give AVA = 3.142 × 20 ÷ 80 = 0.785 cm², with a stroke volume of 62.8 mL.
Limits you should know
- The flow is steady and fills each section. Nothing enters or leaves between the sections you compare.
- The velocities are mean velocities over each section.
- The pressure change that goes with a change of velocity needs the Bernoulli equation, which this page does not work out.
- The heart valve area is arithmetic for checking and learning. It takes the outflow tract as round and the velocity as flat across it. It does not grade the stenosis and it is not medical advice or a diagnosis.
Related pages
- Velocity in one section of any shape: Fluid Velocity Calculator.
- The pressure change that goes with a change of velocity: Bernoulli Equation Calculator.
- Pressure drop in each pipe: Pipe Flow Calculator.
- Flow rate from a volume and a time, and flow units: Flow Rate Calculator.
- Body surface area for the indexed valve area: Body Surface Area Calculator.