A flow rate is how much fluid passes in a given time. Find it from a volume and a time, from an area and a velocity, from a pressure across an opening, or from a pump. Turn it into mass or molar flow, or into any flow unit.

Enter your values

Flow = area × mean velocity, for a pipe, a duct, a channel or a river.

Your values

The average over the whole section. For a river, a float on the surface moves faster than the mean.

Your values are worked out in this browser. They are not sent to a server.

Your result will show here

Fill in the values, then choose the button below them.

How to use this calculator

  1. Choose what you want to work out, for example Flow rate from an area and a velocity or Flow rate from a volume and a time.
  2. Enter what you know and pick a unit for each value.
  3. Choose Calculate. You can change the unit of a result, read the working, and download it as a CSV file.

The formulas

  • From a volume and a time: Q = V ÷ t. A bucket test: fill a container of known size and time it.
  • From an area and a velocity (the continuity equation): Q = A × v, with v the mean velocity. For a round pipe A = π × D² ÷ 4; for a duct or a channel A = width × height.
  • Mass and molar flow: ṁ = ρ × Q and ṅ = ṁ ÷ M, with ρ the density and M the molar mass.
  • Through an orifice or nozzle: Q = Cd × A × √(2 × Δp ÷ ρ). With a K-factor: Q = K × √p.
  • Positive-displacement pump: Q = displacement × speed × volumetric efficiency.
  • To carry a heat load: ṁ = load ÷ (cp × ΔT).
  • Drip rate: drops per minute = volume in mL × drop factor ÷ time in minutes.

Worked examples

A 10 L bucket fills in 30 s, so the flow is 10 ÷ 30 = 0.3333 L/s, which is 20 L/min.

Water moves at 1.5 m/s in a pipe with a 50 mm bore. The area is π × 0.05² ÷ 4 = 0.001963 m², so Q = 0.001963 × 1.5 = 0.002945 m³/s, or 176.7 L/min.

A chilled water circuit carries 50 kW with a 5 °C difference. With cp = 4.18 kJ/(kg·K), the mass flow is 50 ÷ (4.18 × 5) = 2.392 kg/s. With 998.2 kg/m³ that is 143.8 L/min.

A sprinkler with K = 5.6 gpm/√psi at 50 psi passes 5.6 × √50 = 39.6 gpm.

100 m³/h is 1,666.7 L/min, 440.29 US gpm and 58.86 cfm.

1,000 mL over 8 hours with a 20 drops/mL set: 1,000 × 20 ÷ 480 = 41.67 drops per minute (about 42), and 125 mL/h.

Limits you should know

  • Velocities are mean velocities over the area. The fluid in the middle of a pipe or a river moves faster than near the walls.
  • Gases are compressible: a gas volume flow depends on its pressure and temperature. Use the density at the conditions you mean. For flow through a hole at a large pressure drop, use the Orifice Flow Calculator.
  • The pressure drop and the flow of a whole pipe are worked out by the Pipe Flow Calculator. The flow of a centrifugal pump comes from its curve, on the Pump Head Calculator.
  • Discharge coefficients, K-factors, specific heats and drop factors are your own figures from the maker or the data sheet. Example values are rounded.
  • The drip rate is arithmetic for checking and learning. Follow the prescription, local protocol and the device instructions. It is not medical advice.
  • The results are arithmetic for the values you type, not a design approval.