Toolvito

Works on this device

Pump Head Calculator

Find the head a pump must give: the height it lifts the liquid, the pressure it must add, and the losses in the pipes and fittings. Draw the system curve over a range of flows, and see where your pump's curve meets it.

Enter your values

The head a pump must give at a flow: static lift + pressure difference + outlet velocity head + losses in the pipes and fittings.

Your values

The height from the liquid surface on the suction side up to the point of discharge (or to the liquid surface of the upper tank when the pipe ends below it). Below zero when the discharge is lower.

0 for an open tank or sump.

0 for a pipe that ends in an open tank or in the air. A closed tank, a sprinkler or a spray nozzle needs its pressure here.

Tick it for a pipe that ends in the open air. For a pipe that ends below a liquid surface, untick it and give that pipe an exit K of 1 instead.

A head loss you know at this flow, such as a filter, a meter or a heat exchanger from its data sheet.

998.2 kg/m³ is water at about 20 °C, an example. Type the value for your fluid, or fill in an example from the menu above.

1.002 mPa·s is water at about 20 °C, an example. 1 mPa·s is 1 cP.

Pipes of the system

One row for each pipe size, suction side first. The last row is the pipe the liquid leaves by. K: entrance, bends, valves and other fittings of that pipe (the starting values are examples).

This unit is used in every row.

This unit is used in every row.

Your values are worked out in this browser. They are not sent to a server.

Your result will show here

Fill in the values, then choose Calculate.

How to use this calculator

  1. Choose Total dynamic head for one flow, System curve and operating point to compare with a pump curve, or Pump head from two gauge readings for a pump that runs.
  2. Enter the static head: the height from the liquid surface on the suction side up to where the liquid leaves (or to the surface of the upper tank).
  3. Enter the gauge pressures on the suction surface and at the discharge point. Both are 0 for open tanks.
  4. Add one row for each pipe size with its length, inside diameter, roughness and the sum of the K values of its fittings. Suction side first; the last row is the pipe the liquid leaves by.
  5. For the operating point, type or paste the points of your pump's curve (flow and head) from its data sheet.
  6. Choose Calculate.

The formulas

  • Total dynamic head: TDH = static head + (p_discharge − p_suction) ÷ (ρ × g) + outlet velocity head + losses.
  • Losses of each pipe: Darcy-Weisbach h = f × (L ÷ D) × v² ÷ (2g) with the Colebrook friction factor, plus ΣK × v² ÷ (2g) for its fittings. These are the relations of the Pipe Flow Calculator.
  • System curve: the same sum at each flow from the lowest to the highest flow of the pump curve. Operating point: the flow where the pump head equals the system head.
  • From two gauges: H = (p_d − p_s) ÷ (ρ × g) + (z_d − z_s) + (v_d² − v_s²) ÷ (2g).
  • Power given to the liquid: ρ × g × Q × H.

Worked example

10 L/s of water at about 20 °C is lifted 15 m from an open sump to an open outlet. The suction pipe is 5 m of 100 mm steel (K = 2) and the discharge pipe 60 m of 80 mm steel (K = 6), both with a roughness of 0.046 mm.

In the suction pipe the velocity is 1.273 m/s and the loss 0.246 m. In the discharge pipe the velocity is 1.989 m/s and the loss 4.178 m. The water leaves at 1.989 m/s, a velocity head of 0.202 m.

TDH = 15 + 0 + 0.202 + 4.424 = 19.63 m. The pump must add 192.1 kPa, and the power given to the water is 998.2 × 9.80665 × 0.01 × 19.63 = 1.92 kW.

With the example pump curve in the starting rows, the curves meet at 42.81 m³/h and 21.47 m.

Limits you should know

  • The pump curve is joined by straight lines between your points. Use enough points near the working flow.
  • Pressures are gauge pressures on the liquid surfaces; the speed of the liquid on a large tank surface is taken as zero.
  • The suction side is not checked for cavitation. Check the NPSH available against the pump's NPSH required with the Npsh Calculator.
  • The shaft and motor power need the efficiencies: see the Pump Power Calculator. Running cost: Pump Operating Cost Calculator.
  • Pumps in series or in parallel, and pipe networks with branches, are not combined here.
  • The example pump curve, the roughness and the K values are examples. The results are arithmetic for the values you type, not a design approval: codes, the pump maker's data and safety factors decide. This is not professional advice.

Related tools