Works on this device
Pump Head Calculator
Find the head a pump must give: the height it lifts the liquid, the pressure it must add, and the losses in the pipes and fittings. Draw the system curve over a range of flows, and see where your pump's curve meets it.
Enter your values
Check these values
Your values are worked out in this browser. They are not sent to a server.
Your result will show here
Fill in the values, then choose Calculate.
Your result
How it was worked out
How to use this calculator
- Choose Total dynamic head for one flow, System curve and operating point to compare with a pump curve, or Pump head from two gauge readings for a pump that runs.
- Enter the static head: the height from the liquid surface on the suction side up to where the liquid leaves (or to the surface of the upper tank).
- Enter the gauge pressures on the suction surface and at the discharge point. Both are 0 for open tanks.
- Add one row for each pipe size with its length, inside diameter, roughness and the sum of the K values of its fittings. Suction side first; the last row is the pipe the liquid leaves by.
- For the operating point, type or paste the points of your pump's curve (flow and head) from its data sheet.
- Choose Calculate.
The formulas
- Total dynamic head: TDH = static head + (p_discharge − p_suction) ÷ (ρ × g) + outlet velocity head + losses.
- Losses of each pipe: Darcy-Weisbach h = f × (L ÷ D) × v² ÷ (2g) with the Colebrook friction factor, plus ΣK × v² ÷ (2g) for its fittings. These are the relations of the Pipe Flow Calculator.
- System curve: the same sum at each flow from the lowest to the highest flow of the pump curve. Operating point: the flow where the pump head equals the system head.
- From two gauges: H = (p_d − p_s) ÷ (ρ × g) + (z_d − z_s) + (v_d² − v_s²) ÷ (2g).
- Power given to the liquid: ρ × g × Q × H.
Worked example
10 L/s of water at about 20 °C is lifted 15 m from an open sump to an open outlet. The suction pipe is 5 m of 100 mm steel (K = 2) and the discharge pipe 60 m of 80 mm steel (K = 6), both with a roughness of 0.046 mm.
In the suction pipe the velocity is 1.273 m/s and the loss 0.246 m. In the discharge pipe the velocity is 1.989 m/s and the loss 4.178 m. The water leaves at 1.989 m/s, a velocity head of 0.202 m.
TDH = 15 + 0 + 0.202 + 4.424 = 19.63 m. The pump must add 192.1 kPa, and the power given to the water is 998.2 × 9.80665 × 0.01 × 19.63 = 1.92 kW.
With the example pump curve in the starting rows, the curves meet at 42.81 m³/h and 21.47 m.
Limits you should know
- The pump curve is joined by straight lines between your points. Use enough points near the working flow.
- Pressures are gauge pressures on the liquid surfaces; the speed of the liquid on a large tank surface is taken as zero.
- The suction side is not checked for cavitation. Check the NPSH available against the pump's NPSH required with the Npsh Calculator.
- The shaft and motor power need the efficiencies: see the Pump Power Calculator. Running cost: Pump Operating Cost Calculator.
- Pumps in series or in parallel, and pipe networks with branches, are not combined here.
- The example pump curve, the roughness and the K values are examples. The results are arithmetic for the values you type, not a design approval: codes, the pump maker's data and safety factors decide. This is not professional advice.