Works on this device
Npsh Calculator
Find the net positive suction head (NPSH) your system gives a pump, and check it against the NPSH the pump needs. The tool shows each part of the sum with your numbers.
Enter your values
Check these values
Your values are worked out in this browser. They are not sent to a server.
Your result will show here
Fill in the values, then choose Calculate.
Your result
How it was worked out
How to use this calculator
- Choose NPSH available from the suction tank or sump to plan a system, or from a suction gauge reading for a pump that runs.
- Say whether the liquid is open to the air or in a closed tank, and enter the pressure. On high ground you can let the tool work out the atmospheric pressure from the height of the site.
- Enter the height of the liquid surface above the pump inlet: below zero when the pump sits above the liquid (a suction lift).
- Enter the losses of the suction pipe as a head, or let the tool work them out from the pipe, its fittings and the flow.
- For water, enter the temperature and the tool works out the vapour pressure. For another liquid, type its vapour pressure and density.
- Type the NPSHr from the pump curve at the same flow to see the margin, the ratio and the lowest liquid level the pump can work with.
The formulas
- NPSH available from the tank: NPSHa = (p − pv) ÷ (ρ × g) + z − h_L. p is the absolute pressure on the liquid surface, pv the vapour pressure of the liquid at its temperature, z the height of the surface above the pump inlet (below zero for a suction lift) and h_L the losses of the suction pipe.
- From a suction gauge: NPSHa = (p_gauge + p_atmosphere − pv) ÷ (ρ × g) + z_gauge + v² ÷ (2g).
- Margin and ratio: margin = NPSHa − NPSHr; ratio = NPSHa ÷ NPSHr, both at the same flow.
- Suction pipe losses: Darcy-Weisbach with the Colebrook friction factor, plus ΣK × v² ÷ (2g) for the fittings.
- Vapour pressure of water: the IAPWS-IF97 saturation-pressure equation (region 4), from 0 °C to 373.946 °C.
- Atmospheric pressure from height: the standard atmosphere (ISO 2533), p = 101,325 Pa × (1 − 0.0065 × h ÷ 288.15)^5.25588.
- Suction specific speed: S = n × √Q ÷ NPSHr^(3/4) at the best efficiency point, with Q the flow of one impeller eye. Turned round, it gives a first estimate of NPSHr.
Worked example
A pump draws water at 20 °C (998.2 kg/m³) from an open sump at sea level (101.325 kPa). It sits 3 m above the water surface, and the suction pipe loses 0.5 m at the working flow.
The vapour pressure of water at 20 °C is 2.339 kPa. The pressure head is 101,325 ÷ (998.2 × 9.80665) = 10.351 m and the vapour pressure head 0.239 m. NPSHa = 10.351 − 0.239 − 3 − 0.5 = 6.612 m.
The pump curve gives NPSHr = 4 m at this flow. The margin is 2.612 m and the ratio 1.653. With a margin of 1 m kept, the pump could stand up to 4.612 m above the water.
The same sump at a site 1,500 m high (84.56 kPa) with water at 60 °C (983.2 kg/m³, vapour pressure 19.95 kPa) gives only 3.201 m: less than the NPSHr of 4 m.
Example values
The menu above the fields fills in rounded example values for water at 10, 20, 40, 60 and 80 °C: the temperature, the density and the viscosity. The vapour pressure of water is worked out from the temperature. For any other liquid, type its own values from a data sheet.
Limits you should know
- NPSHr belongs to the pump. It comes from the maker's test, usually as NPSH3, where the head has already dropped by 3 %. The estimate from the suction specific speed is only a first guide.
- The margin a pump needs depends on the pump, the liquid and the service. Take it from the pump maker or a guide such as ANSI/HI 9.6.1; this page does not choose it for you.
- The flow on a large tank surface is taken as at rest. Gas or air in the liquid, vortices at the suction inlet and the acceleration head of reciprocating pumps are not worked out; add them to the losses if you know them.
- Check NPSHa at the highest flow and the highest liquid temperature the pump will see, and at the lowest liquid level.
- The results are arithmetic for the values you type, not a design approval. This is not professional advice.
Related pages
- The head the pump must give the whole system: Pump Head Calculator.
- Losses of a pipe with fittings in more detail: Pipe Flow Calculator.
- Suction and discharge pressure from heads: Head Pressure Calculator.
- Power of the pump: Pump Power Calculator.