Toolvito

Works on this device

Pump Power Calculator

Find the power a pump gives the liquid, the power its shaft needs and the electrical power its motor takes in. You can also turn a power round into a flow or a head, and work out the energy and cost of running.

Enter your values

The power a pump gives the liquid, the power its shaft needs and the electrical power its motor takes in.

Your values

The total dynamic head at this flow: the lift, the pressure to add and the pipe losses. The Pump Head Calculator works it out.

998.2 kg/m³ is water at about 20 °C, an example. For a slurry, type the density of the mixture.

At this flow, from the pump curve. With it, the tool shows the shaft power. From the pump or motor data sheet at this duty. No value is built in.

The motor, and the speed drive if there is one, multiplied together. With the pump efficiency, the tool shows the electrical input power.

Your values are worked out in this browser. They are not sent to a server.

Your result will show here

Fill in the values, then choose Calculate.

How to use this calculator

  1. Choose Pump power from flow and head, Flow or head that a known power can drive, or Energy use and running cost.
  2. Enter the flow and the total head of the pump. For a hydraulic (oil) pump, or when you know pressures, choose a pressure rise instead of a head.
  3. Enter the density of the liquid. For a slurry, use the density of the mixture.
  4. Type the pump efficiency and the motor efficiency from the data sheets to see the shaft power and the electrical input power. Leave them empty for the hydraulic power alone.
  5. Choose Calculate. A result with the input power has a button that carries it to the energy and cost choice.

The formulas

  • Hydraulic power (the power given to the liquid): P_h = ρ × g × Q × H, or P_h = Δp × Q with Δp = ρ × g × H the pressure rise.
  • Shaft (brake) power: P_shaft = P_h ÷ η_pump.
  • Electrical input power: P_in = P_shaft ÷ η_motor (with a speed drive, multiply its efficiency into η_motor).
  • Overall (wire-to-water) efficiency: P_h ÷ P_in = η_pump × η_motor.
  • In everyday units: kW = Q (m³/h) × H (m) × SG ÷ (367.1 × η), and hp = Q (US gpm) × H (ft) × SG ÷ (3,960 × η), with SG the density ÷ 1,000 kg/m³.
  • Energy: kWh = input power (kW) × hours. Cost = kWh × your price for one kWh.

Worked example

A pump moves 30 m³/h of water at about 20 °C (998.2 kg/m³) against a total head of 25 m. The hydraulic power is 998.2 × 9.80665 × (30 ÷ 3,600) × 25 = 2,039 W, or 2.039 kW.

With a pump efficiency of 70 %, the shaft power is 2.039 ÷ 0.70 = 2.913 kW. With a motor efficiency of 90 %, the motor takes in 2.913 ÷ 0.90 = 3.237 kW. The overall efficiency is 63 %.

Running for 8 hours, it uses 3.237 × 8 = 25.90 kWh. At an example price of 0.15 for one kWh, that costs 3.88.

Turned round: a shaft power of 5 kW at 70 % efficiency can move 0.0143 m³/s (51.49 m³/h) of the same water against 25 m.

Limits you should know

  • The efficiencies are your figures from the pump curve and the motor data at this duty. No value is built in, and the example values are only for trying the tool.
  • A pump runs at one point on its own curve. This page works out the power for a duty you give; it does not choose a pump or a motor size.
  • For a slurry or a thick liquid, the maker's head and efficiency already change with the liquid. Vacuum pumps and compressors move a gas and need other relations.
  • The electricity price is the one you type; standing charges, demand charges and tax are not counted. For a yearly running cost, use the Pump Operating Cost Calculator.
  • The results are arithmetic for the values you type, not a design approval. This is not professional advice.