Works on this device
Pump Operating Cost Calculator
Find the electricity a pump uses and what it costs. You type the power, the efficiencies, the flow and the head of your own pump, and your own price for one kWh: none is built in. The costs are estimates from the figures you type.
Enter your values
Check these values
Your values are worked out in this browser. They are not sent to a server.
Your result will show here
Fill in the values, then choose Calculate.
Your result
How it was worked out
How to use this calculator
- Choose Running cost of a pump from its power.
- Say what you know: the electrical power that the pump takes in, or the rated power of its motor.
- Type that power. For a rated power, also type the load on the motor and the efficiency of the motor.
- Type the hours that the pump runs each day and the days each week.
- Type your electricity price for one kWh, from your bill. Type the flow if you want the cost for each cubic metre.
- Choose Calculate. Try an example fills the empty boxes with example values, so that you can see how an option works.
What each option does
- Running cost from the power: the energy and the cost for an hour, a day, a month and a year, and the cost for each cubic metre if you type the flow.
- Pump power and cost from flow and head: the hydraulic power, the shaft power and the input power from the efficiencies you type, and the running cost.
- Cost at a new pump speed: the power, the flow and the head at another speed by the affinity laws, for the same running hours or for the same volume pumped.
The formulas
- Energy in kWh = input power in kW × hours of running. Cost = energy × price for one kWh.
- Input power from the rating plate = rated power of the motor × load ÷ efficiency of the motor.
- Hydraulic power = density × g × flow × head, with g = 9.80665 m/s². One litre of water a second lifted by one metre needs 9.80665 W.
- Input power = hydraulic power ÷ efficiency of the pump ÷ efficiency of the motor and drive.
- Cost for each cubic metre = input power ÷ flow × price for one kWh.
- Affinity laws for the same pump in the same pipes: flow changes in step with the speed, head with the square of the speed, and power with the cube of the speed.
Worked examples
Running cost. A pump takes in 750 W and runs 8 hours a day, every day. It uses 6 kWh a day and 2,190 kWh a year. At 0.15 for one kWh, that is 0.90 a day, 27.38 a month and 328.50 a year. With a flow of 12 m³/h it moves 35,040 m³ a year, for 0.0625 kWh each.
Flow and head. A pump moves 20 m³/h of water against a head of 30 m. The hydraulic power is 1,000 × 9.80665 × 0.0055556 × 30 = 1,634.4 W. With a pump efficiency of 70% and a motor efficiency of 90%, the input power is 1,634.4 ÷ 0.70 ÷ 0.90 = 2,594.4 W. For 8 hours a day that is 7,575.51 kWh a year, which costs 1,136.33 at 0.15 for one kWh.
A new speed. A pump takes in 1.5 kW at 2,900 revolutions per minute. At 2,320 revolutions per minute the speed ratio is 0.8, so the power is 1.5 × 0.8³ = 0.768 kW. For the same 2,920 hours the cost falls from 657.00 to 336.38 a year. To move the same volume, the pump runs 3,650 hours and costs 420.48, a saving of 236.52.
Where to find your figures
- Input power: the label of the pump, or a measurement with a power meter. A label in horsepower usually gives the power at the shaft.
- Flow, head and pump efficiency: the pump curve in the data sheet at your working point, or a flow meter and pressure gauges.
- Efficiency of the motor: the rating plate or the data sheet of the motor.
- Electricity price for one kWh: the unit rate on your bill.
- The values that Try an example fills in are for trying the tool. They are not the data of any real pump and not current prices.
Limits you should know
- One power, one flow and one head are used for all the running hours. A pump with a speed drive or a changing head needs a measured average.
- The affinity laws are an ideal model. They hold for a pump that works mostly against friction, such as a pool filter loop or a heating loop. A pump that lifts liquid to a height, or feeds a system under pressure, saves less, and below some speed it moves no liquid at all.
- The efficiency of the pump, the motor and the drive falls at low speed, so the real saving is a little smaller.
- Only the energy is priced. Standing charges, a demand charge, tax, water and upkeep are not counted.
- For a speed that changes through the year and for the payback of a speed drive, use the motor energy savings calculator. For a heat pump, use the heating cost calculator.
- Costs for a month and a year are rounded once to 2 decimal places, and a half is rounded away from zero. The costs are estimates, not a bill, and the tool does not choose a pump or a motor.