Find the flow through an orifice, the pressure it needs, the bore for a flow or the discharge coefficient from a test. There are also choices for a hole in a tank and for a gas through a hole or a nozzle.

Enter your values

The flow of a liquid (or a gas at a small pressure drop) through an orifice, from the pressure difference or the height of liquid.

Your values

Upstream pressure minus downstream pressure, measured at the taps of the orifice.

998.2 kg/m³ is water at about 20 °C, an example. Use the value for your fluid.

0.61 is a usual textbook figure for a sharp-edged orifice, an example. Use the coefficient for your orifice from its standard, its maker or a test.

Your values are worked out in this browser. They are not sent to a server.

Your result will show here

Fill in the values, then choose Calculate.

How to use this calculator

  1. Choose what you want to find. For a liquid, start with Flow through an orifice. For a gas at a large pressure drop, choose Gas through a hole or nozzle.
  2. Enter the discharge coefficient Cd of your orifice. The menu above the fields fills in rounded textbook examples; the right value comes from the standard of your orifice, its maker or a test.
  3. For an orifice plate, nozzle or venturi in a pipe, choose that and enter the pipe diameter, so the velocity of approach is counted.
  4. Choose Calculate. The working shows each step with your numbers.

The orifice equation

Q = Cd × A × √(2 × Δp ÷ ρ) ÷ √(1 − β⁴). Q is the flow, A the area of the bore, Δp the pressure difference, ρ the density and β = bore diameter ÷ pipe diameter. For a hole in a tank wall β = 0, so the last factor is 1.

From a height of liquid h: Δp = ρ × g × h, so Q = Cd × A × √(2gh). This is Torricelli's law with a discharge coefficient.

Turned round: Δp = (ρ ÷ 2) × (Q × √(1 − β⁴) ÷ (Cd × A))², and Cd = Q × √(1 − β⁴) ÷ (A × √(2Δp ÷ ρ)). For the bore in a pipe, the area a comes from Q² = a² × (Cd² × 2Δp ÷ ρ + Q² ÷ A_pipe²).

Gas through a hole or nozzle

For a gas at a large pressure drop the tool uses isentropic flow of an ideal gas with a discharge coefficient. The flow is choked (sonic at the throat) when p₂ ÷ p₁ is at or below (2 ÷ (k + 1))^(k ÷ (k − 1)), which is 0.528 for k = 1.4. Then ṁ = Cd × A × p₁ × √(k ÷ (R T₁)) × (2 ÷ (k + 1))^((k + 1) ÷ (2(k − 1))), and a lower downstream pressure does not raise the flow.

Worked examples

Water (998.2 kg/m³) through a sharp-edged 25 mm hole with Cd = 0.61 and a pressure difference of 25 kPa: A = 0.0004909 m², √(2 × 25,000 ÷ 998.2) = 7.077 m/s, so Q = 0.61 × 0.0004909 × 7.077 = 0.002119 m³/s, or 2.119 L/s.

A tank with 2 m of water above a 25 mm hole (Cd 0.61) lets out 1.875 L/s. The jet would leave at √(2 × 9.80665 × 2) = 6.263 m/s without losses.

Air at 20 °C and 600 kPa gauge through a 3 mm hole (Cd 0.61, k = 1.4, 28.96 g/mol) into the open air: the pressure ratio is 101.325 ÷ 701.325 = 0.144, below 0.528, so the flow is choked at 25.69 kg/h.

Example discharge coefficients

These rounded textbook values are only a start. The coefficient changes with the shape and edge of the opening, the β ratio, the tap positions and the Reynolds number.

Example discharge coefficients (rounded; check your own source)
Opening Example Cd
Sharp-edged orifice about 0.61
Short tube, 2 to 3 diameters long about 0.82
Well-rounded nozzle about 0.97

Limits you should know

  • The tool uses your discharge coefficient. It does not work Cd out from a standard such as ISO 5167 or AGA Report No. 3, and it does not size the plate thickness.
  • For a liquid the fluid is incompressible. For a gas, the liquid choices hold only when the pressure difference is a few percent of the absolute pressure; use the gas choice otherwise.