Works on this device
Orifice Flow Calculator
Find the flow through an orifice, the pressure it needs, the bore for a flow or the discharge coefficient from a test. There are also choices for a hole in a tank and for a gas through a hole or a nozzle.
Enter your values
Check these values
Your values are worked out in this browser. They are not sent to a server.
Your result will show here
Fill in the values, then choose Calculate.
Your result
How it was worked out
How to use this calculator
- Choose what you want to find. For a liquid, start with Flow through an orifice. For a gas at a large pressure drop, choose Gas through a hole or nozzle.
- Enter the discharge coefficient Cd of your orifice. The menu above the fields fills in rounded textbook examples; the right value comes from the standard of your orifice, its maker or a test.
- For an orifice plate, nozzle or venturi in a pipe, choose that and enter the pipe diameter, so the velocity of approach is counted.
- Choose Calculate. The working shows each step with your numbers.
The orifice equation
Q = Cd × A × √(2 × Δp ÷ ρ) ÷ √(1 − β⁴). Q is the flow, A the area of the bore, Δp the pressure difference, ρ the density and β = bore diameter ÷ pipe diameter. For a hole in a tank wall β = 0, so the last factor is 1.
From a height of liquid h: Δp = ρ × g × h, so Q = Cd × A × √(2gh). This is Torricelli's law with a discharge coefficient.
Turned round: Δp = (ρ ÷ 2) × (Q × √(1 − β⁴) ÷ (Cd × A))², and Cd = Q × √(1 − β⁴) ÷ (A × √(2Δp ÷ ρ)). For the bore in a pipe, the area a comes from Q² = a² × (Cd² × 2Δp ÷ ρ + Q² ÷ A_pipe²).
Gas through a hole or nozzle
For a gas at a large pressure drop the tool uses isentropic flow of an ideal gas with a discharge coefficient. The flow is choked (sonic at the throat) when p₂ ÷ p₁ is at or below (2 ÷ (k + 1))^(k ÷ (k − 1)), which is 0.528 for k = 1.4. Then ṁ = Cd × A × p₁ × √(k ÷ (R T₁)) × (2 ÷ (k + 1))^((k + 1) ÷ (2(k − 1))), and a lower downstream pressure does not raise the flow.
Worked examples
Water (998.2 kg/m³) through a sharp-edged 25 mm hole with Cd = 0.61 and a pressure difference of 25 kPa: A = 0.0004909 m², √(2 × 25,000 ÷ 998.2) = 7.077 m/s, so Q = 0.61 × 0.0004909 × 7.077 = 0.002119 m³/s, or 2.119 L/s.
A tank with 2 m of water above a 25 mm hole (Cd 0.61) lets out 1.875 L/s. The jet would leave at √(2 × 9.80665 × 2) = 6.263 m/s without losses.
Air at 20 °C and 600 kPa gauge through a 3 mm hole (Cd 0.61, k = 1.4, 28.96 g/mol) into the open air: the pressure ratio is 101.325 ÷ 701.325 = 0.144, below 0.528, so the flow is choked at 25.69 kg/h.
Example discharge coefficients
These rounded textbook values are only a start. The coefficient changes with the shape and edge of the opening, the β ratio, the tap positions and the Reynolds number.
| Opening | Example Cd |
|---|---|
| Sharp-edged orifice | about 0.61 |
| Short tube, 2 to 3 diameters long | about 0.82 |
| Well-rounded nozzle | about 0.97 |
Limits you should know
- The tool uses your discharge coefficient. It does not work Cd out from a standard such as ISO 5167 or AGA Report No. 3, and it does not size the plate thickness.
- For a liquid the fluid is incompressible. For a gas, the liquid choices hold only when the pressure difference is a few percent of the absolute pressure; use the gas choice otherwise.
- The gas choice is for an ideal gas through a hole, a leak or a nozzle. An orifice plate in a gas line needs the expansibility factor of its standard, and steam needs steam-table properties; neither is built here.
- The pressure difference across an orifice plate is measured at its taps. Much of it is won back downstream, so the lasting pressure loss of the line is smaller.
- The results are arithmetic for the values you type. They are not a design approval: codes, standards and the maker's data decide. This is not professional advice.