Cv is the flow coefficient of a valve: the US gallons per minute of water it passes with a pressure drop of 1 psi. Use it to find the flow, the pressure drop or the Cv a duty needs, for a liquid, a gas or steam.

Enter your values

The flow of a liquid that a pressure drop pushes through a valve of known Cv.

Your values

From the valve maker's data for the opening you mean (the rated Cv is for the fully open valve).

The pressure before the valve minus the pressure after it.

The density of the liquid divided by the density of water. Water is 1.

Your values are worked out in this browser. They are not sent to a server.

Your result will show here

Fill in the values, then choose the button below them.

How to use this calculator

  1. Choose what you want to work out, for example Cv needed for a liquid flow or Pressure drop across a valve, from Cv.
  2. Enter the values you know and pick a unit for each one. The specific gravity of water is 1.
  3. Choose Calculate. The result also shows the same valve as Kv, the working with your numbers, and a CSV download.

The formulas

  • Liquid flow: Q = Cv × √(Δp ÷ SG), with Q in US gallons per minute (gpm), Δp the pressure drop in psi and SG the specific gravity (the density of the liquid ÷ the density of water).
  • Cv needed: Cv = Q × √(SG ÷ Δp). Pressure drop: Δp = SG × (Q ÷ Cv)².
  • Valves in series (the same flow through each): 1 ÷ Cv² = 1 ÷ Cv₁² + 1 ÷ Cv₂² + … In parallel (the same drop across each): Cv = Cv₁ + Cv₂ + …
  • Cv and Kv: Kv is the flow in m³/h at a drop of 1 bar. Kv = 0.8649777 × Cv and Cv = 1.156099 × Kv. The factor is (1 gpm in m³/h) × √(1 bar ÷ 1 psi), from the exact definitions of the gallon, the inch, the pound and the bar.
  • Loss coefficient K: Δp = K × ρ × v² ÷ 2 in the bore d. For water this gives Kv = (π × d² ÷ 4) × √(2 × 1 bar ÷ (1,000 kg/m³ × K)), about 0.04 × d² ÷ √K with d in mm.
  • Gas and steam (IEC 60534-2-1, turbulent flow): W = N6 × Kv × Y × √(x × p1 × ρ1), with x = Δp ÷ p1, Y = 1 − x ÷ (3 × Fγ × xT) and Fγ = γ ÷ 1.40. The flow chokes when x reaches Fγ × xT. N6 = √1000 = 31.62 for W in kg/h, p1 in bar and ρ1 in kg/m³.

Worked examples

A valve with Cv = 10 and a drop of 4 psi passes water at 10 × √(4 ÷ 1) = 20 gpm. The same valve has Kv = 8.650.

A liquid with SG = 0.85 must flow at 50 gpm with a drop of 9 psi. The valve needs Cv = 50 × √(0.85 ÷ 9) = 15.37 (Kv 13.29).

A control valve (Cv 12), two open ball valves (Cv 50 each) and a strainer (Cv 35) in series act as one valve of Cv 10.81. At 20 gpm of water the group loses 3.424 psi, of which the control valve takes 81 %.

A fitting with K = 5 in a 2 in bore has Kv = 46.15, which is Cv = 53.35.

Air at 100 psi absolute and 68 °F through a valve of Cv 10 and xT 0.7, with a 20 psi drop: x = 0.2, Y = 0.9048 and the flow is 1,833.8 lb/h (831.8 kg/h), about 400.5 standard cubic feet per minute at 60 °F.

Limits you should know

  • A liquid that flashes or cavitates at a large pressure drop gives less flow than the formula. That limit needs the valve's pressure recovery factor FL and the vapour pressure: use the Control Valve Sizing Calculator, which also covers reducers, valve authority and a full sizing.
  • The gas relation takes the piping geometry factor Fp as 1 and the flow as turbulent. xT and γ come from the valve maker and the gas data; the example values are not data for your valve.
  • The ideal gas choice uses Z = 1. For steam or a real gas at high pressure, type the density at the inlet, for example from the Steam Table Calculator.
  • Cv is measured with water at about 60 °F and Kv with water at 5 to 40 °C. The conversion treats both as the same water, as valve makers do.
  • The Cv of a real valve, at each opening, comes from its maker. The tool does not hold valve data.
  • The results are arithmetic for the values you type, not a design approval. This is not professional advice.