Cv is the flow coefficient of a valve: the US gallons per minute of water it passes with a pressure drop of 1 psi. Use it to find the flow, the pressure drop or the Cv a duty needs, for a liquid, a gas or steam.
Enter your values
Check these values
Your values are worked out in this browser. They are not sent to a server.
Your result will show here
Fill in the values, then choose the button below them.
Your result
How it was worked out
How to use this calculator
- Choose what you want to work out, for example Cv needed for a liquid flow or Pressure drop across a valve, from Cv.
- Enter the values you know and pick a unit for each one. The specific gravity of water is 1.
- Choose Calculate. The result also shows the same valve as Kv, the working with your numbers, and a CSV download.
The formulas
- Liquid flow: Q = Cv × √(Δp ÷ SG), with Q in US gallons per minute (gpm), Δp the pressure drop in psi and SG the specific gravity (the density of the liquid ÷ the density of water).
- Cv needed: Cv = Q × √(SG ÷ Δp). Pressure drop: Δp = SG × (Q ÷ Cv)².
- Valves in series (the same flow through each): 1 ÷ Cv² = 1 ÷ Cv₁² + 1 ÷ Cv₂² + … In parallel (the same drop across each): Cv = Cv₁ + Cv₂ + …
- Cv and Kv: Kv is the flow in m³/h at a drop of 1 bar. Kv = 0.8649777 × Cv and Cv = 1.156099 × Kv. The factor is (1 gpm in m³/h) × √(1 bar ÷ 1 psi), from the exact definitions of the gallon, the inch, the pound and the bar.
- Loss coefficient K: Δp = K × ρ × v² ÷ 2 in the bore d. For water this gives Kv = (π × d² ÷ 4) × √(2 × 1 bar ÷ (1,000 kg/m³ × K)), about 0.04 × d² ÷ √K with d in mm.
- Gas and steam (IEC 60534-2-1, turbulent flow): W = N6 × Kv × Y × √(x × p1 × ρ1), with x = Δp ÷ p1, Y = 1 − x ÷ (3 × Fγ × xT) and Fγ = γ ÷ 1.40. The flow chokes when x reaches Fγ × xT. N6 = √1000 = 31.62 for W in kg/h, p1 in bar and ρ1 in kg/m³.
Worked examples
A valve with Cv = 10 and a drop of 4 psi passes water at 10 × √(4 ÷ 1) = 20 gpm. The same valve has Kv = 8.650.
A liquid with SG = 0.85 must flow at 50 gpm with a drop of 9 psi. The valve needs Cv = 50 × √(0.85 ÷ 9) = 15.37 (Kv 13.29).
A control valve (Cv 12), two open ball valves (Cv 50 each) and a strainer (Cv 35) in series act as one valve of Cv 10.81. At 20 gpm of water the group loses 3.424 psi, of which the control valve takes 81 %.
A fitting with K = 5 in a 2 in bore has Kv = 46.15, which is Cv = 53.35.
Air at 100 psi absolute and 68 °F through a valve of Cv 10 and xT 0.7, with a 20 psi drop: x = 0.2, Y = 0.9048 and the flow is 1,833.8 lb/h (831.8 kg/h), about 400.5 standard cubic feet per minute at 60 °F.
Limits you should know
- A liquid that flashes or cavitates at a large pressure drop gives less flow than the formula. That limit needs the valve's pressure recovery factor FL and the vapour pressure: use the Control Valve Sizing Calculator, which also covers reducers, valve authority and a full sizing.
- The gas relation takes the piping geometry factor Fp as 1 and the flow as turbulent. xT and γ come from the valve maker and the gas data; the example values are not data for your valve.
- The ideal gas choice uses Z = 1. For steam or a real gas at high pressure, type the density at the inlet, for example from the Steam Table Calculator.
- Cv is measured with water at about 60 °F and Kv with water at 5 to 40 °C. The conversion treats both as the same water, as valve makers do.
- The Cv of a real valve, at each opening, comes from its maker. The tool does not hold valve data.
- The results are arithmetic for the values you type, not a design approval. This is not professional advice.
Related pages
- The same calculations in metric units with Kv: Valve Kv Calculator.
- The pressure drop of the pipe and its fittings around the valve: Pipe Flow Calculator.
- Flow units and mass flow: Flow Rate Calculator.
- Flow through an orifice plate or a nozzle: Orifice Flow Calculator.