Steam Table Calculator

Find the properties of water and steam from what you know: the temperature or pressure of saturated steam, the pressure and temperature of water or superheated steam, the pressure with an enthalpy or entropy, or wet steam with its dryness fraction. You get the density, specific volume, enthalpy, internal energy, entropy, specific heats and speed of sound by IAPWS-IF97, the formulation used for industrial steam tables.

Enter your values

Your values

Your values are worked out in this browser. They are not sent to a server.

Your result will show here

Fill in the values, then choose Calculate.

Second IAPWS-IF97 answer with viscosity, conductivity and a T-s or h-s chart

Second IAPWS-IF97 answer with viscosity, conductivity and a chart

Uses the state, saturation point or table of the result above. The server works it out again with CoolProp's own IAPWS-IF97 code, adds the viscosity and thermal conductivity (IAPWS 2008 and 2011), compares with the scientific formulation IAPWS-95 and draws a chart. Its lowest pressure is the triple-point pressure, 0.611657 kPa.

The calculator above works on your device. When you run a task in this section, Toolvito receives the values and result you submit to make the file or run the check. Download the result within one hour after the job finishes. Choose Delete files now to request earlier removal. The hourly cleanup normally removes files within one to two hours after completion.

How to use the steam table calculator

  1. Choose what you know. Saturated water and steam needs one temperature or pressure. Water or superheated steam needs a pressure and a temperature. A pressure and an enthalpy or entropy finds the temperature, or the dryness fraction if the steam is wet. Wet steam needs the dryness fraction x.
  2. Say whether the pressure is absolute or gauge (above the air). Steam tables use absolute pressure; most gauges read gauge pressure. Each value has a unit menu, also for BTU/lb and °F.
  3. Press Calculate. A steam table over a range lists saturated water and steam at evenly spaced temperatures or pressures, with a chart.
  4. The box under the result works out the same state on the server with a second IAPWS-IF97 code, adds viscosity and thermal conductivity, compares with the scientific formulation IAPWS-95 and draws the state on a T-s or h-s (Mollier) chart.

What the values mean

  • Saturated water and steam can exist together; at a given pressure the temperature is fixed (the boiling point). hf is the enthalpy of the water, hg of the steam and hfg = hg − hf the latent heat.
  • Wet steam with dryness fraction x is a mixture: h = hf + x hfg, and the same for v, u and s.
  • Superheated steam is hotter than the boiling point at its pressure (the superheat); compressed (subcooled) water is colder. Above 22.064 MPa and 373.946 °C, the critical point, water is a supercritical fluid.
  • Enthalpy and entropy count from liquid water at the triple point (0.01 °C), as in all steam tables.

The formulation

  • IAPWS-IF97 (IAPWS R7-97(2012)) splits the range into regions: 1 for liquid water, 2 for steam, 3 near the critical point, 4 for the saturation line and 5 for steam from 800 °C to 2000 °C. Each region has its own equation; the page uses all five.
  • Region 3 gives the pressure from the density, so the page finds the density that gives your pressure. A pressure with an enthalpy or entropy is solved for the temperature by halving an interval on the same equations.
  • cp, cv and the speed of sound come from derivatives of the equations.

Worked example

Steam at 1 MPa absolute and 250 °C: the saturation temperature is 179.89 °C, so the steam is superheated by 70.1 K; h = 2943.2 kJ/kg, s = 6.9266 kJ/(kg·K) and v = 0.23274 m³/kg.

Expanded at constant entropy to 100 kPa, it ends as wet steam: with sf = 1.3026 and sg = 7.3588 kJ/(kg·K) the dryness fraction is x = 0.9286, so h = 417.44 + 0.9286 × 2257.51 = 2513.85 kJ/kg. The ideal turbine work is 2943.22 − 2513.85 = 429.37 kJ/kg.

Limits you should know

  • IAPWS-IF97 covers 0 °C to 800 °C up to 100 MPa and 800 °C to 2000 °C up to 50 MPa. Ice and metastable states are not covered.
  • Close to the critical point, within about 1 K, the saturated values of IAPWS-IF97 implementations differ by several per cent from each other and from IAPWS-95; the server box shows both.
  • Printed steam tables from older formulations (IFC-67) can differ in the last digit.