Steam Consumption Calculator
Work out how much steam a load needs: a flow of water or another fluid, a batch in a tank or jacketed vessel, a known heat rate, or a single-effect evaporator. The heat each kilogram of steam gives up comes from IAPWS-IF97 steam properties at your pressure.
Enter your values
Check these values
Your values are worked out in this browser. They are not sent to a server.
Your result will show here
Fill in the values, then choose Calculate.
Your result
How it was worked out
How to use this calculator
- Choose the load: a flow to heat, a batch to heat in a time, a known heat rate, or an evaporator.
- Enter the steam pressure (gauge or absolute) and say whether the steam is dry, wet or superheated.
- Say whether the condensate leaves as saturated water, or cooler at a temperature you type.
- Enter the load: the flow or the mass, the specific heat and the two temperatures; or the heat rate; or the feed and the water to boil off.
- Choose Calculate to get the steam in kg/h (or lb/h) and the working.
The formulas
- Heat to the load: Q = m × c × (T2 − T1) for a fluid or a batch.
- Heat per kg of steam: Δh = h(steam) − h(condensate). For dry saturated steam that leaves as saturated water, Δh is the latent heat hfg. Wet steam has h = hf + x × hfg.
- Steam needed: steam = Q ÷ Δh (÷ (1 − the share lost on the way), when you type a loss).
- Evaporator: Q = V × hg + (F − V) × hf − F × h(feed), at the boiling point of the evaporator pressure. Steam economy = V ÷ steam.
- Steam and water enthalpies: IAPWS-IF97, regions 1, 2 and 4.
Worked example
Heat 2 m³/h of water (density 1,000 kg/m³, c = 4.186 kJ/(kg·K)) from 10 °C to 60 °C with dry saturated steam at 3 bar gauge. The mass flow is 0.5556 kg/s, so Q = 0.5556 × 4.186 × 50 = 116.28 kW. At 401.325 kPa absolute the steam condenses at 143.73 °C and gives up hfg = 2,132.97 kJ/kg. Steam = 116.28 ÷ 2,132.97 = 0.05451 kg/s, which is 196.25 kg/h.
Limits you should know
- The specific heat is one mean value; for a large temperature range use the mean over that range. The density, specific heat and loss are your figures; the examples are for trying the tool.
- Start-up (warming the pipes and vessel), the loss of the steam lines and the trap losses are not counted. The Steam Heat Loss Calculator gives the loss of a pipe.
- The evaporator choice takes the liquid as water: no boiling point rise and no heat of solution.
- The fuel that makes the steam depends on the boiler: use the Boiler Efficiency Calculator. For the flash steam and heat in returned condensate, see the Condensate Return Calculator; for heat without steam, the Sensible Heat Calculator.
- Steam pressure up to 16.5 MPa (165 bar) absolute. This is an estimate for planning and checking, not a design approval.