Condensate Return Calculator

Work out how much heat, water and fuel your boiler saves when condensate comes back instead of cold make-up water, and how much flash steam forms when hot condensate is let down to a lower pressure.

Enter your values

Condensate that goes back to the boiler brings its heat and its treated water with it. Compare it with cold make-up water.

Your values

At the boiler feed tank, after any flash steam has left.

The water that would replace the condensate if it were sent to drain.

Your boiler's figure (an example is filled in). The Boiler Efficiency Calculator can work it out.

With it, the tool gives the share of condensate returned and the make-up water still needed.

From your fuel bill, in the main unit of your money. No price is built in.

Water, its treatment and the drain charge for 1 m³, in the main unit of your money. No price is built in.

Your values are worked out in this browser. They are not sent to a server.

Your result will show here

Fill in the values, then choose Calculate.

How to use this calculator

  1. Choose condensate return for the savings, or flash steam for the steam that forms after a steam trap.
  2. For the savings, enter the condensate flow that returns, its temperature at the feed tank, the make-up water temperature, the boiler efficiency and the hours in a year.
  3. To see money, type your own prices for fuel and for make-up water. No price is built in; the example prices are only for trying the tool.
  4. For flash steam, enter the pressure before and after the let-down (gauge or absolute) and the condensate flow.
  5. Choose Calculate.

The formulas

  • Heat brought back = condensate flow × (h of the returned condensate − h of the make-up water).
  • Fuel saved = heat brought back ÷ boiler efficiency. Water saved = the volume of make-up water replaced.
  • Flash steam share x = (h1 − hf2) ÷ hfg2, where h1 is the enthalpy of the condensate before the let-down, and hf2 and hfg2 are the enthalpy of saturated water and the latent heat at the lower pressure.
  • Water and steam enthalpies: IAPWS-IF97, regions 1, 2 and 4.

Worked examples

Condensate from traps at 10 bar gauge (saturated, 184.12 °C, h1 = 781.43 kJ/kg) goes to a tank open to the air (0 bar gauge: hf2 = 418.99 kJ/kg, hfg2 = 2,256.54 kJ/kg). Flash share = (781.43 − 418.99) ÷ 2,256.54 = 16.06%. Of 1,000 kg/h of condensate, 160.62 kg/h flashes to steam.

2,000 kg/h of condensate returns at 90 °C instead of make-up water at 15 °C. Each kilogram brings back 313.98 kJ, so the heat brought back is 174.44 kW. Over 6,000 hours that is 1,046.6 MWh of heat, or 1,308.3 MWh of fuel at a boiler efficiency of 80%, and 12,011 m³ of water.

Limits you should know

  • Steady flows, no heat lost in the let-down; the flash vessel or tank is at the pressure you type.
  • The return savings compare with cold make-up water. Lower blowdown, fewer chemicals and the cost of the return pump and pipes are not counted separately.
  • This tool does not size condensate lines or flash vessels: that needs the two-phase flow of water and flash steam.
  • For the steam a process uses, see the Steam Consumption Calculator; for the loss of steam pipes, the Steam Heat Loss Calculator; for the boiler efficiency, the Boiler Efficiency Calculator.
  • Steam pressure up to 16.5 MPa (165 bar) absolute. This is an estimate for planning and checking, not a design approval.