Toolvito

Works on this device

Valve Kv Calculator

Kv is the flow coefficient of a valve in metric units: the cubic metres per hour of water it passes with a pressure drop of 1 bar. Use it to find the flow, the pressure drop or the Kv a duty needs, and to convert Kv and Cv.

Enter your values

The flow of a liquid that a pressure drop pushes through a valve of known Kv.

Your values

From the valve maker's data for the opening you mean (the rated Kv is for the fully open valve).

The pressure before the valve minus the pressure after it.

The density of the liquid divided by the density of water. Water is 1.

Your values are worked out in this browser. They are not sent to a server.

Your result will show here

Fill in the values, then choose the button below them.

How to use this calculator

  1. Choose what you want to work out, for example Kv needed for a liquid flow or Convert Kv and Cv.
  2. Enter the values you know and pick a unit for each one. The specific gravity of water is 1.
  3. Choose Calculate. The result also shows the same valve as Cv, the working with your numbers, and a CSV download.

The formulas

  • Liquid flow: Q = Kv × √(Δp ÷ SG), with Q in m³/h, Δp the pressure drop in bar and SG the specific gravity (the density of the liquid ÷ the density of water).
  • Kv needed: Kv = Q × √(SG ÷ Δp). Pressure drop: Δp = SG × (Q ÷ Kv)².
  • Valves in series (the same flow through each): 1 ÷ Kv² = 1 ÷ Kv₁² + 1 ÷ Kv₂² + … In parallel (the same drop across each): Kv = Kv₁ + Kv₂ + …
  • Kv and Cv: Cv is the flow in US gallons per minute at a drop of 1 psi. Cv = 1.156099 × Kv and Kv = 0.8649777 × Cv. The factor is (1 gpm in m³/h) × √(1 bar ÷ 1 psi), from the exact definitions of the gallon, the inch, the pound and the bar.
  • Loss coefficient K (also written ζ): Δp = K × ρ × v² ÷ 2 in the bore d. For water this gives Kv = (π × d² ÷ 4) × √(2 × 1 bar ÷ (1,000 kg/m³ × K)), about 0.04 × d² ÷ √K with d in mm.
  • Gas and steam (IEC 60534-2-1, turbulent flow): W = 31.62 × Kv × Y × √(x × p1 × ρ1), with W in kg/h, p1 in bar, ρ1 in kg/m³, x = Δp ÷ p1, Y = 1 − x ÷ (3 × Fγ × xT) and Fγ = γ ÷ 1.40. The flow chokes when x reaches Fγ × xT.

Worked examples

A valve with Kv = 10 and a drop of 0.5 bar passes water at 10 × √0.5 = 7.071 m³/h. The same valve has Cv = 11.56.

Water must flow at 12 m³/h with a drop of 0.8 bar. The valve needs Kv = 12 × √(1 ÷ 0.8) = 13.42 (Cv 15.51).

A control valve (Kv 10), two open ball valves (Kv 40 each) and a strainer (Kv 30) in series act as one valve of Kv 8.994. At 7 m³/h of water the group loses 0.6057 bar.

Air at 7 bar absolute and 20 °C through a valve of Kv 10 and xT 0.7, with a 1.5 bar drop: x = 0.2143, Y = 0.898 and the flow is 1,003 kg/h, about 776 normal m³/h (0 °C, 101.325 kPa).

Limits you should know

  • A liquid that flashes or cavitates at a large pressure drop gives less flow than the formula. That limit needs the valve's pressure recovery factor FL and the vapour pressure: use the Control Valve Sizing Calculator, which also covers reducers, valve authority and a full sizing.
  • The gas relation takes the piping geometry factor Fp as 1 and the flow as turbulent. xT and γ come from the valve maker and the gas data; the example values are not data for your valve.
  • The ideal gas choice uses Z = 1. For steam or a real gas at high pressure, type the density at the inlet, for example from the Steam Table Calculator.
  • Kv is measured with water at 5 to 40 °C and Cv with water at about 60 °F. The conversion treats both as the same water, as valve makers do.
  • The Kv of a real valve, at each opening, comes from its maker. The tool does not hold valve data.
  • The results are arithmetic for the values you type, not a design approval. This is not professional advice.