Works on this device
Valve Kv Calculator
Kv is the flow coefficient of a valve in metric units: the cubic metres per hour of water it passes with a pressure drop of 1 bar. Use it to find the flow, the pressure drop or the Kv a duty needs, and to convert Kv and Cv.
Enter your values
Check these values
Your values are worked out in this browser. They are not sent to a server.
Your result will show here
Fill in the values, then choose the button below them.
Your result
How it was worked out
How to use this calculator
- Choose what you want to work out, for example Kv needed for a liquid flow or Convert Kv and Cv.
- Enter the values you know and pick a unit for each one. The specific gravity of water is 1.
- Choose Calculate. The result also shows the same valve as Cv, the working with your numbers, and a CSV download.
The formulas
- Liquid flow: Q = Kv × √(Δp ÷ SG), with Q in m³/h, Δp the pressure drop in bar and SG the specific gravity (the density of the liquid ÷ the density of water).
- Kv needed: Kv = Q × √(SG ÷ Δp). Pressure drop: Δp = SG × (Q ÷ Kv)².
- Valves in series (the same flow through each): 1 ÷ Kv² = 1 ÷ Kv₁² + 1 ÷ Kv₂² + … In parallel (the same drop across each): Kv = Kv₁ + Kv₂ + …
- Kv and Cv: Cv is the flow in US gallons per minute at a drop of 1 psi. Cv = 1.156099 × Kv and Kv = 0.8649777 × Cv. The factor is (1 gpm in m³/h) × √(1 bar ÷ 1 psi), from the exact definitions of the gallon, the inch, the pound and the bar.
- Loss coefficient K (also written ζ): Δp = K × ρ × v² ÷ 2 in the bore d. For water this gives Kv = (π × d² ÷ 4) × √(2 × 1 bar ÷ (1,000 kg/m³ × K)), about 0.04 × d² ÷ √K with d in mm.
- Gas and steam (IEC 60534-2-1, turbulent flow): W = 31.62 × Kv × Y × √(x × p1 × ρ1), with W in kg/h, p1 in bar, ρ1 in kg/m³, x = Δp ÷ p1, Y = 1 − x ÷ (3 × Fγ × xT) and Fγ = γ ÷ 1.40. The flow chokes when x reaches Fγ × xT.
Worked examples
A valve with Kv = 10 and a drop of 0.5 bar passes water at 10 × √0.5 = 7.071 m³/h. The same valve has Cv = 11.56.
Water must flow at 12 m³/h with a drop of 0.8 bar. The valve needs Kv = 12 × √(1 ÷ 0.8) = 13.42 (Cv 15.51).
A control valve (Kv 10), two open ball valves (Kv 40 each) and a strainer (Kv 30) in series act as one valve of Kv 8.994. At 7 m³/h of water the group loses 0.6057 bar.
Air at 7 bar absolute and 20 °C through a valve of Kv 10 and xT 0.7, with a 1.5 bar drop: x = 0.2143, Y = 0.898 and the flow is 1,003 kg/h, about 776 normal m³/h (0 °C, 101.325 kPa).
Limits you should know
- A liquid that flashes or cavitates at a large pressure drop gives less flow than the formula. That limit needs the valve's pressure recovery factor FL and the vapour pressure: use the Control Valve Sizing Calculator, which also covers reducers, valve authority and a full sizing.
- The gas relation takes the piping geometry factor Fp as 1 and the flow as turbulent. xT and γ come from the valve maker and the gas data; the example values are not data for your valve.
- The ideal gas choice uses Z = 1. For steam or a real gas at high pressure, type the density at the inlet, for example from the Steam Table Calculator.
- Kv is measured with water at 5 to 40 °C and Cv with water at about 60 °F. The conversion treats both as the same water, as valve makers do.
- The Kv of a real valve, at each opening, comes from its maker. The tool does not hold valve data.
- The results are arithmetic for the values you type, not a design approval. This is not professional advice.
Related pages
- The same calculations in US units with Cv: Valve Cv Calculator. Both pages use the same relations and give the same answer for one valve.
- The pressure drop of the pipe and its fittings around the valve: Pipe Flow Calculator.
- Flow units and mass flow: Flow Rate Calculator.