Toolvito

Works on this device

Pipe Expansion Calculator

A pipe gets longer when it heats up and shorter when it cools. Work out the change in length of a run, the stress and force when the pipe cannot move, and the length of an expansion loop or offset that takes the movement up.

Enter your values

How much a pipe run gets longer when it heats up, or shorter when it cools: ΔL = α × L × ΔT.

Your values

12 × 10⁻⁶ per K is an example for carbon steel. Use the value for your material and temperature range, or fill in an example from the menu above.

Between two fixed points (anchors), or the whole run that is free to move.

Lower than the installed temperature for a pipe that cools: it then gets shorter.

Your values are worked out in this browser. They are not sent to a server.

Your result will show here

Fill in the values, then choose Calculate.

How to use this calculator

  1. Choose Change in length, Stress and force in a pipe held at both ends, or Expansion loop or offset leg.
  2. Fill in the coefficient of expansion α and, where asked, Young's modulus E. The menu above the fields fills in rounded examples for common materials; use your maker's values where you have them.
  3. Enter the length and the two temperatures: when the pipe is installed and when it works.
  4. For a loop, type the allowable stress from your piping code. Choose Calculate and read the working.

The formulas

  • Change in length: ΔL = α × L × ΔT, with ΔT = operating temperature − installed temperature.
  • Pipe held at both ends: the stress is σ = E × α × ΔT and the force on each anchor is F = σ × A, with A = π × (OD² − ID²) ÷ 4 the area of the wall.
  • Guided cantilever method for a leg at right angles: the bending stress is σ = 3 × E × D × Δ ÷ L², so the leg needs L = √(3 × E × D × Δ ÷ S_A). D is the outside diameter, Δ the expansion that leg takes and S_A the allowable stress range.
  • In a U-loop midway between two anchors, each of the two legs takes half the total expansion. In an L-bend or offset, one leg takes the whole expansion of the other.

Worked examples

A 30 m carbon steel line (α = 12 × 10⁻⁶ per K) is installed at 20 °C and works at 120 °C. It grows by 12 × 10⁻⁶ × 30 × 100 = 0.036 m, or 36 mm.

A 20 ft PVC run (α = 3.0 × 10⁻⁵ per °F) that warms by 70 °F grows by 0.504 in.

Held at both ends, the steel line (E = 200 GPa) gets a stress of 200 × 10⁹ × 12 × 10⁻⁶ × 100 = 240 MPa. With a 160 mm outside diameter and a 6 mm wall (2,903 mm² of metal), each anchor takes 696.7 kN.

With S_A = 150 MPa (an example value), an L-bend that takes the 36 mm needs a leg of √(3 × 200 × 10⁹ × 0.16 × 0.036 ÷ 150 × 10⁶) = 4.8 m. A U-loop in the middle needs two legs of 3.39 m.

Example values in the menus

The menus fill in rounded values for trying the tool. α and E change with the grade of the material and with the temperature; piping codes list mean values for each temperature range.

Example values (rounded; check them against your own source)
Material α E
Carbon steel about 12 × 10⁻⁶/K about 200 GPa
Austenitic stainless steel about 17 × 10⁻⁶/K about 193 GPa
Copper about 17 × 10⁻⁶/K about 117 GPa
PVC-U about 3.0 × 10⁻⁵/°F (54 × 10⁻⁶/K) about 3 GPa
Polyethylene (HDPE) about 1.0 × 10⁻⁴/°F (180 × 10⁻⁶/K) not given: it depends strongly on the time and the temperature

Limits you should know

  • The guided cantilever method leaves out the flexibility of the bends, so it gives a longer leg than a full stress analysis. It does not check anchors, guides, supports or the nozzles of equipment.
  • The allowable stress range S_A comes from your piping code (for example ASME B31.1 or B31.3) for the material and the temperatures. The tool does not hold code values.
  • The restrained stress holds only while the material stays elastic; pressure stress and buckling are not included.
  • Plastic pipes creep and their makers give their own rules for loops and supports. Use the maker's method for them.
  • The results are arithmetic for checking and learning, not a design approval. This is not professional advice.