Works on this device
Thermal Expansion Calculator
Work out how much a part grows or shrinks when its temperature changes: its length, its diameter, its area or its volume. You can also find the expansion of a liquid or of water, the gap that closes or the stress when the part is held, and the coefficient α from a test.
Enter your values
Check these values
Your values are worked out in this browser. They are not sent to a server.
Your result will show here
Fill in the values, then choose Calculate.
Your result
How it was worked out
How to use this calculator
- Choose what you want: linear expansion, a cylinder or hole, an area, a solid volume, a liquid, water, held expansion, or a conversion of the coefficient.
- Type the coefficient α (or β for a liquid), or fill in an example for the material from the menu. Use the value from your own data when it matters.
- Enter the size and the start and end temperatures. An end temperature below the start gives shrinking.
- Choose Calculate. Each result has a unit menu: mm, in, °C, °F and more.
The formulas
- Length: ΔL = α × L0 × ΔT, so L1 = L0 × (1 + α × ΔT). Turned round: α = ΔL ÷ (L0 × ΔT) and ΔT = ΔL ÷ (α × L0).
- Diameter of a shaft, ring or hole: ΔD = α × D0 × ΔT. A hole grows like the metal around it.
- Area: A1 = A0 × (1 + α × ΔT)², close to ΔA = 2α × A0 × ΔT. Volume of a solid: V1 = V0 × (1 + α × ΔT)³, close to ΔV = 3α × V0 × ΔT.
- Liquid: ΔV = β × V0 × ΔT, with β the mean volumetric coefficient. Water: V2 = V1 × v2 ÷ v1 from the specific volume of IAPWS-IF97.
- Held: once the gap is closed, the strain (α × L0 × ΔT − gap) ÷ L0 gives a stress σ = E × strain.
Worked examples
A steel bar 10 m long (α = 12 × 10⁻⁶/K) warms from 20 °C to 70 °C: ΔL = 12 × 10⁻⁶ × 10 × 50 = 0.006 m, or 6 mm. A steel shaft of 50 mm grows by 12 × 10⁻⁶ × 50 × 50 = 0.03 mm in diameter.
A 50 L tank of petrol with β = 950 × 10⁻⁶/K that warms by 20 K grows by 950 × 10⁻⁶ × 50 × 20 = 0.95 L.
200 L of water in a heating system at 1.5 bar gauge, heated from 20 °C to 70 °C, grows by 4.178 L (2.089%), from a density of 998.27 kg/m³ to 977.85 kg/m³.
If the 10 m steel bar has a 5 mm gap and is held after that, the gap closes at 61.67 °C. At 70 °C, 1 mm of expansion is held back: strain = 0.0001 and σ = 210 GPa × 0.0001 = 21 MPa in compression.
Limits you should know
- One mean coefficient over the temperature range. α of most materials rises with temperature; tables give the mean value between two temperatures.
- The material examples are rounded values or the design values of the Eurocodes, for trying the tool. Your material may differ.
- Held expansion takes rigid ends and an elastic, straight part; long parts in compression can buckle. For pipe runs with anchors and loops, use the Pipe Expansion Calculator; for thermal stress in more cases, the Thermal Stress Calculator; for shrink fits, the Thermal Expansion Fit Calculator.
- The expansion of a gas at a fixed pressure follows the gas laws: see the Gas Law Calculator.
- Water: liquid water from 0 °C up to its boiling point at the pressure you type (IAPWS-IF97 region 1, up to 350 °C).
- This is arithmetic for learning and checking, not a design approval and not professional advice.