Toolvito

Works on this device

PCB Thermal Resistance Calculator

Find how well a printed circuit board carries heat away from a hot part. Work out the thermal resistance of a grid of thermal vias, of the layers through the board and of copper paths such as traces and thermal relief spokes, and the junction temperature of a part for its power.

Enter your values

Use this for the thermal resistance of an array of plated vias that carries heat from a part to the other side of the board.

Your values

The diameter of the hole, as your board maker states it.

Board makers often give the finished hole size. The drill is then larger by twice the plating.

Often about 20 to 25 µm (about 1 mil). Your board maker states the value.

All the thermal vias under the pad, such as 9 for a 3 by 3 grid.

Type it to count the board material under the pad as well, beside the vias.

Type it to see the temperature drop across this path.

More options

About 400 W/(m·K) is a rounded example for pure copper. Plated copper can be a little lower.

Your values are worked out in this browser. They are not sent to a server.

Your result will show here

Fill in the values, then choose Calculate.

How to use this calculator

  1. Choose what you want to work out, for example Thermal vias under a pad (through the board).
  2. Type the sizes from your board design: hole, plating, board thickness and the number of vias, or the thickness of each layer, or the length and width of the copper.
  3. Check the conductivities. The starting values are examples; use the figures from your board and material data sheets.
  4. Choose Calculate. Type a heat flow to see the temperature drop, and carry the result into Junction temperature for a power.

The formulas

  • One part: R = L ÷ (k × A), with L the length of the heat path, k the thermal conductivity and A the area across the path (Fourier's law). R is in K/W, which is the same as °C/W.
  • In a row (layers): R = R1 + R2 + … Side by side (vias, spokes): 1 ÷ R = 1 ÷ R1 + 1 ÷ R2 + …
  • A thermal via is a copper tube: R = board thickness ÷ (k × π ÷ 4 × (outer² − inner²)), with the inner diameter the hole minus twice the plating. A fill adds π ÷ 4 × inner² of its own material side by side. N equal vias give R ÷ N.
  • Along copper: R = length ÷ (k × width × thickness), divided by the number of paths side by side.
  • Junction temperature: Tj = T at the cool end + P × (sum of the resistances from the junction outwards).

Worked examples

  • One via, 0.3 mm drilled, 25 µm plating, 1.6 mm board, k = 400 W/(m·K): the copper cross-section is 0.0215984 mm², so R = 0.0016 ÷ (400 × 0.0000000215984) = 185.198 K/W. Nine such vias side by side: 20.5776 K/W.
  • The same nine vias under a 25 mm² pad, with a board of 0.3 W/(m·K) between them (24.3638 mm²): the board adds 218.904 K/W side by side, so the total is 18.8095 K/W. About 91.4% of the heat goes through the vias.
  • Through 100 mm² of a 1.6 mm board (two 35 µm copper layers and 1.53 mm of board at 0.3 W/(m·K)): about 51.002 K/W, of which the board gives 51 K/W. The two copper layers add only 0.00175 K/W.
  • A thermal relief with four spokes 0.3 mm wide and 0.25 mm long in 35 µm copper: 59.5238 K/W for each spoke, 14.881 K/W for all four.
  • A part making 2 W through 3 + 20 + 12 = 35 K/W from a 40 °C heat sink: Tj = 40 + 2 × 35 = 110 °C.

Limits you should know

  • The model is one-dimensional: heat flows straight along each path. Copper planes spread heat sideways, and the board also loses heat to the air, so a real board often runs cooler. Use the results to compare designs and as a first estimate; check hot designs with a thermal simulation or a measurement.
  • No board material data is built in. Glass-epoxy boards conduct far less through their thickness than along it, and products differ, so use your laminate's data sheet.
  • Junction-to-case values on data sheets are measured on stated test boards. This is not a safety rating; parts near their limits need a measurement.
  • For the current a via can carry see the Via Current Calculator; for trace width and its electrical resistance, the PCB Trace Width Calculator; for walls, pipes and other heat paths, the Thermal Resistance Calculator.