Works on this device
PCB Thermal Resistance Calculator
Find how well a printed circuit board carries heat away from a hot part. Work out the thermal resistance of a grid of thermal vias, of the layers through the board and of copper paths such as traces and thermal relief spokes, and the junction temperature of a part for its power.
Enter your values
Check these values
Your values are worked out in this browser. They are not sent to a server.
Your result will show here
Fill in the values, then choose Calculate.
Your result
How it was worked out
How to use this calculator
- Choose what you want to work out, for example Thermal vias under a pad (through the board).
- Type the sizes from your board design: hole, plating, board thickness and the number of vias, or the thickness of each layer, or the length and width of the copper.
- Check the conductivities. The starting values are examples; use the figures from your board and material data sheets.
- Choose Calculate. Type a heat flow to see the temperature drop, and carry the result into Junction temperature for a power.
The formulas
- One part: R = L ÷ (k × A), with L the length of the heat path, k the thermal conductivity and A the area across the path (Fourier's law). R is in K/W, which is the same as °C/W.
- In a row (layers): R = R1 + R2 + … Side by side (vias, spokes): 1 ÷ R = 1 ÷ R1 + 1 ÷ R2 + …
- A thermal via is a copper tube: R = board thickness ÷ (k × π ÷ 4 × (outer² − inner²)), with the inner diameter the hole minus twice the plating. A fill adds π ÷ 4 × inner² of its own material side by side. N equal vias give R ÷ N.
- Along copper: R = length ÷ (k × width × thickness), divided by the number of paths side by side.
- Junction temperature: Tj = T at the cool end + P × (sum of the resistances from the junction outwards).
Worked examples
- One via, 0.3 mm drilled, 25 µm plating, 1.6 mm board, k = 400 W/(m·K): the copper cross-section is 0.0215984 mm², so R = 0.0016 ÷ (400 × 0.0000000215984) = 185.198 K/W. Nine such vias side by side: 20.5776 K/W.
- The same nine vias under a 25 mm² pad, with a board of 0.3 W/(m·K) between them (24.3638 mm²): the board adds 218.904 K/W side by side, so the total is 18.8095 K/W. About 91.4% of the heat goes through the vias.
- Through 100 mm² of a 1.6 mm board (two 35 µm copper layers and 1.53 mm of board at 0.3 W/(m·K)): about 51.002 K/W, of which the board gives 51 K/W. The two copper layers add only 0.00175 K/W.
- A thermal relief with four spokes 0.3 mm wide and 0.25 mm long in 35 µm copper: 59.5238 K/W for each spoke, 14.881 K/W for all four.
- A part making 2 W through 3 + 20 + 12 = 35 K/W from a 40 °C heat sink: Tj = 40 + 2 × 35 = 110 °C.
Limits you should know
- The model is one-dimensional: heat flows straight along each path. Copper planes spread heat sideways, and the board also loses heat to the air, so a real board often runs cooler. Use the results to compare designs and as a first estimate; check hot designs with a thermal simulation or a measurement.
- No board material data is built in. Glass-epoxy boards conduct far less through their thickness than along it, and products differ, so use your laminate's data sheet.
- Junction-to-case values on data sheets are measured on stated test boards. This is not a safety rating; parts near their limits need a measurement.
- For the current a via can carry see the Via Current Calculator; for trace width and its electrical resistance, the PCB Trace Width Calculator; for walls, pipes and other heat paths, the Thermal Resistance Calculator.