Solve the Sabine equation of room acoustics for any one value: the reverberation time RT60, the room volume, or the total absorption area. You can also find the mean absorption coefficient a target time needs.

Enter your values

Your values

In m² sabins (metric) or ft² sabins: the sum of each surface area times its absorption coefficient, plus people and objects.

Floor, ceiling and walls together. Type it to see the mean absorption coefficient.

More options

343 m/s (1,125 ft/s) is air at about 20 °C.

Your values are worked out in this browser. They are not sent to a server.

Your result will show here

Fill in the values, then choose Calculate.

How to use this calculator

  1. Choose what you want to find.
  2. Type the other values and choose their units. Use cubic feet and square feet (sabins) for the imperial form.
  3. Under More options you can change the speed of sound.
  4. Choose Calculate. The result shows the answer, the constant used and the working.

The formula

  • Sabine equation: RT60 = 24 ln(10) × V ÷ (c × A), with the room volume V, the total absorption area A and the speed of sound c.
  • Metric form: RT60 = 0.161 × V ÷ A, with V in m³ and A in m² sabins (c = 343 m/s).
  • Imperial form: RT60 = 0.049 × V ÷ A, with V in ft³ and A in ft² sabins (c = 1,125 ft/s).
  • Turned round: V = RT60 × A ÷ 0.161 and A = 0.161 × V ÷ RT60. The mean absorption coefficient is ᾱ = A ÷ S, with S the total area of the surfaces.

Worked examples

  • A room of 200 m³ with 40 m² sabins of absorption: RT60 = 0.1611 × 200 ÷ 40 = 0.806 s.
  • For RT60 = 0.8 s in that room you need A = 0.1611 × 200 ÷ 0.8 = 40.28 m² sabins. With 220 m² of surfaces that is a mean coefficient of 0.183.
  • A room of 10,000 ft³ with 500 ft² sabins: RT60 = 0.0491 × 10,000 ÷ 500 = 0.98 s.

Limits you should know

  • Sabine assumes a diffuse sound field: sound spread evenly in a room whose length, width and height are not very different, with the absorption spread around.
  • It suits live rooms. With a mean absorption coefficient above about 0.2, the Eyring formula gives a shorter, more realistic time.
  • Absorption changes with frequency, so work out each octave band on its own.