Works on this device
Sound Pressure Level Calculator
Turn a sound pressure into a sound pressure level in dB SPL and back, and work out how the level changes with distance from a source. You can also go from sound power to sound pressure level, find how loud a speaker plays with an amplifier, and work out the sound exposure level of an event.
Enter your values
Check these values
Your values are worked out in this browser. They are not sent to a server.
Your result will show here
Fill in the values, then choose Calculate.
Your result
How it was worked out
How to use this calculator
- Choose what you want to work out, for example Sound pressure level from pressure, or pressure from level.
- Choose what you want to find, then type the values you know and choose their units.
- Choose Calculate. The result shows the answer and the working with your numbers.
The formulas
- Sound pressure level: Lp = 20 × log10(p ÷ p0), with the RMS sound pressure p and p0 = 20 µPa in air (1 µPa in water). Back: p = p0 × 10^(Lp ÷ 20).
- Level at another distance (inverse-square law): L2 = L1 − 20 × log10(r2 ÷ r1). Twice the distance is 6 dB less, in a free field.
- Sound power level: Lw = 10 × log10(W ÷ 1 pW).
- From sound power to sound pressure level: Lp = Lw + 10 × log10(Q ÷ (4π r²)), with r in metres and the directivity factor Q (1 in open space, 2 on a hard floor).
- Speaker: level = sensitivity at 1 W, 1 m + 10 × log10(watts) − 20 × log10(metres).
- Sound exposure level: SEL = Leq + 10 × log10(T ÷ 1 s).
Worked examples
- A sound pressure of 1 Pa RMS: Lp = 20 × log10(1 ÷ 0.00002) = 20 × log10(50,000) = 93.98 dB SPL. This is the 94 dB of many sound level calibrators.
- 90 dB at 1 m from a machine outdoors is 90 − 20 × log10(10) = 70 dB at 10 m.
- A source of sound power level 100 dB on a hard floor (Q = 2), 5 m away: 100 + 10 × log10(2 ÷ (4π × 25)) = 100 − 21.96 = 78.04 dB.
- A speaker of 88 dB (1 W, 1 m) with 100 W, heard at 4 m: 88 + 20 − 12.04 = 95.96 dB SPL. For 100 dB SPL at 4 m it needs 10^((100 − 88 + 12.04) ÷ 10) = 253.6 W.
- An event with Leq = 85 dB over 60 s has SEL = 85 + 17.78 = 102.78 dB.
Limits you should know
- Levels at a distance use the free-field, point-source model. Indoors, near large sources, near barriers or over long distances outdoors (where air absorbs sound) the real level differs. The Decibel Distance Calculator covers distance in more depth.
- All pressures are RMS values. The level of a short peak (dB peak) is a different measure.
- To add the levels of several sources, use the Decibel Addition Calculator. For decibel units such as dBm and dBV, use the Decibel Calculator. For sound intensity in W/m², use the Sound Intensity Calculator.
- For the noise dose of a worker over a day, use the Noise Exposure Calculator.
- This calculator works with numbers you type. It does not measure sound, and it is not a hearing assessment.