Toolvito

Works on this device

Decibel Calculator

Work out the decibels between two powers, voltages or sound pressures, turn decibels back into a ratio, and convert levels such as 30 dBm, 0 dBu or 94 dB SPL into watts, volts or pascals. You can also add up the gains and losses of a chain of stages.

Enter your values

Gain or loss in decibels between two powers, two voltages or two sound pressures.

Your values

Watts, W/m² and joules are power quantities. Volts, amps and pascals are root-power (field) quantities.

Type both values in the same unit.

Your values are worked out in this browser. They are not sent to a server.

Your result will show here

Fill in the values, then choose Calculate.

How to use this calculator

  1. Choose what you want to work out, for example Decibels from two values or a ratio.
  2. Choose the kind of quantity. Power, intensity and energy use 10 × log10. Voltage, current and sound pressure use 20 × log10.
  3. Type the values. For a level such as dBm or dBV, first choose the decibel unit, then type the value or the level.
  4. Choose Calculate. The result shows the answer, the other forms of it and the working.

The 10 and 20 rules

A decibel compares two values on a log scale. For a power quantity (watts, W/m², joules): dB = 10 × log10(P2 ÷ P1). For a root-power quantity (volts, amps, pascals): dB = 20 × log10(V2 ÷ V1).

Power goes with the square of the voltage across the same resistance, so both rules give the same number of decibels for the same change. 3 dB is about twice the power (10 × log10 2 = 3.0103). 6 dB is about twice the voltage (20 × log10 2 = 6.0206). 10 dB is ten times the power. 20 dB is ten times the voltage.

Back from decibels: power ratio = 10^(dB ÷ 10) and voltage ratio = 10^(dB ÷ 20). A negative number of decibels is a loss.

Decibel units with a reference

A level with a named reference is an absolute value. The calculator uses these references:

Decibel units and their references
Unit Reference Rule
dBm 1 milliwatt 10 × log10
dBW 1 watt (0 dBW = 30 dBm) 10 × log10
dBV 1 volt RMS 20 × log10
dBu 0.7746 volt RMS (√0.6 V: 1 mW in 600 Ω) 20 × log10
dBmV 1 millivolt RMS 20 × log10
dBµV 1 microvolt RMS 20 × log10
dB SPL 20 micropascals RMS, in air (ISO 1683) 20 × log10
dBFS digital full scale 20 × log10

Worked examples

  • Power from 1 W to 100 W: 10 × log10(100) = 20 dB. Voltage from 1 V to 2 V: 20 × log10(2) = 6.0206 dB.
  • A gain of 3 dB is a power ratio of 10^0.3 = 1.99526 and a voltage ratio of 10^0.15 = 1.41254.
  • 30 dBm is 1 W, which is 0 dBW. Across 50 Ω that is √(1 × 50) = 7.0711 V RMS, or 16.9897 dBV.
  • A sound pressure of 1 Pa RMS is 20 × log10(1 ÷ 0.00002) = 93.9794 dB SPL.
  • An amplifier of 20 dB, a cable that loses 3.5 dB and a splitter that loses 7 dB give 20 − 3.5 − 7 = 9.5 dB in total. With −10 dBm at the input the output is −0.5 dBm, which is 0.891251 mW.

Limits you should know

  • Voltages, currents and sound pressures are RMS values. A peak value gives a different number of decibels.
  • Voltage and power ratios match only across the same resistance. To change a power into a voltage, type the resistance.
  • To add or average decibel levels, such as two machines that run at once, use the Decibel Addition Calculator. Levels do not add like plain numbers: 60 dB and 60 dB make about 63 dB.
  • For sound pressure under water, levels at a distance and speaker loudness, use the Sound Pressure Level Calculator or the Decibel Distance Calculator. For a signal-to-noise ratio, use the Signal to Noise Ratio Calculator.
  • The loudness line is a rough rule (10 dB more sounds about twice as loud), not a measurement of how loud a sound is.
  • This calculator does not measure sound. A sound level meter or a calibrated microphone does that.

Related tools