Works on this device
Signal to Noise Ratio Calculator
Find the signal-to-noise ratio (SNR) from two powers, two RMS voltages or two levels in decibels. You can also find the signal level a target SNR needs, and the best SNR of an ideal analog-to-digital converter with N bits.
Enter your values
Check these values
Your values are worked out in this browser. They are not sent to a server.
Your result will show here
Fill in the values, then choose Calculate.
Your result
How it was worked out
How to use this calculator
- Choose how you know the signal and the noise: as powers, as RMS voltages, or as levels in decibels.
- Type both values. If your signal reading was taken with the noise present, tick the box for signal + noise.
- Choose Calculate. The result shows the SNR in dB and as a ratio, with the working.
The formulas
- From powers: SNR = 10 × log10(Ps ÷ Pn).
- From RMS voltages, currents or sound pressures: SNR = 20 × log10(Vs ÷ Vn).
- From levels in the same decibel unit: SNR = signal level − noise level. So the signal level needed is the noise level + SNR.
- Signal measured with the noise: for powers S = (S + N) − N; for RMS voltages S = √((S + N)² − N²), because noise that is not related to the signal adds as power.
- Ideal N-bit converter, full-scale sine wave: SNR = 20 × log10(2^N × √1.5) = 6.02 × N + 1.76 dB. Oversampling adds 10 × log10(fs ÷ (2 × bandwidth)). Effective bits: ENOB = (SINAD − 1.76) ÷ 6.02.
Worked examples
- A signal of 10 mW over noise of 0.01 mW: 10 × log10(1,000) = 30 dB.
- 500 mV RMS of signal over 5 mV RMS of noise: 20 × log10(100) = 40 dB.
- A signal at −60 dBm and noise at −95 dBm: −60 − (−95) = 35 dB.
- An ideal 16-bit converter: 6.0206 × 16 + 1.7609 = 98.09 dB. A converter with a measured SINAD of 74 dB has an ENOB of (74 − 1.7609) ÷ 6.0206 = 12.00 bits.
Limits you should know
- Measure the signal and the noise in the same bandwidth and at the same point. To work out a noise power from the bandwidth and the temperature, use the Noise Floor Calculator.
- The converter formula is for an ideal converter and a full-scale sine wave. Real converters reach less; their data sheets give the real figure.
- The noise added by amplifiers and receivers is worked out with the noise figure: see the Noise Figure Calculator. For the sample rate a signal needs, see the Nyquist Frequency Calculator.
- For decibel units such as dBm and dBV, see the Decibel Calculator.