Noise Figure Calculator
Change a noise figure in dB into a noise factor and a noise temperature, and back. Work out the noise figure of a chain of stages with Friis's formula, of a cable or attenuator, of an antenna system, of an analog-to-digital converter, or of an amplifier from its noise densities.
Enter your values
Check these values
Your values are worked out in this browser. They are not sent to a server.
Your result will show here
Fill in the values, then choose Calculate.
Your result
How it was worked out
How to use this calculator
- Choose what you want to work out, for example Cascaded noise figure of stages in a chain (Friis).
- For a cascade, type each stage in the order the signal passes it, from the antenna or input: its gain in dB (a loss is negative) and its noise figure in dB.
- Choose Calculate. The result shows the noise figure, the noise factor, the noise temperature and the working.
The formulas
- Noise factor and noise figure: F = 10^(NF ÷ 10) and NF = 10 × log10(F). F is the SNR at the input divided by the SNR at the output.
- Noise temperature: Te = T0 × (F − 1) and F = 1 + Te ÷ T0, with the standard reference temperature T0 = 290 K.
- Friis's formula for a cascade: F = F1 + (F2 − 1) ÷ G1 + (F3 − 1) ÷ (G1 × G2) + ..., with F and G as ratios, not dB.
- Passive loss L at temperature T: F = 1 + (L − 1) × T ÷ 290 K. At 290 K the noise figure equals the loss.
- System noise temperature: Tsys = Ta + Te(feed line) + L × Te(receiver), at the antenna terminals.
- ADC: NF = full-scale power (dBm) − SNR − 10 × log10(bandwidth) + 173.98 dB.
- Amplifier: F = 1 + (en² + (in × Rs)²) ÷ (4 k T0 Rs). The lowest noise figure is at Rs = en ÷ in.
Worked examples
- A noise figure of 3 dB is a noise factor of 10^0.3 = 1.99526 and a noise temperature of 290 × 0.99526 = 288.63 K.
- A receiver of five stages: cable (−1 dB, NF 1 dB), low-noise amplifier (20 dB, NF 0.8 dB), filter (−2 dB, NF 2 dB), mixer (−7 dB, NF 8 dB) and IF amplifier (25 dB, NF 4 dB). Friis gives F = 1.77805, so the chain has NF = 2.499 dB (225.64 K) and 35 dB of gain.
- A feed line with 1 dB of loss at 290 K before a receiver with NF = 1.5 dB gives 2.5 dB in total. With an antenna at 50 K the system noise temperature is 275.70 K.
- A converter with a full scale of 2 V peak to peak in 50 Ω (10 dBm), an SNR of 70 dB and a sample rate of 200 MHz (bandwidth 100 MHz): NF = 10 − 70 − 80 + 173.98 = 33.98 dB.
- An amplifier with en = 4 nV/√Hz and in = 1 pA/√Hz from a 1 kΩ source: NF = 3.14 dB. With a 4 kΩ source it would reach its lowest, 1.76 dB.
Limits you should know
- All noise figures assume matched stages and a source at 290 K. Mismatch, the image noise of mixers and bandwidths that differ from stage to stage are not included.
- The amplifier formula takes the voltage and current noise as unrelated and flat with frequency. It does not use the noise parameters (Fmin, Rn, Γopt) of a transistor at radio frequencies.
- For the SNR of a signal, see the Signal to Noise Ratio Calculator. For the noise power in a bandwidth, see the Noise Floor Calculator. For a whole radio link, see the Link Budget Calculator.
- For plain decibel conversions, see the Decibel Calculator.