Works on this device
Protein Extinction Coefficient Calculator
Find the molar extinction coefficient of a protein at 280 nm from its amino acid sequence, and use it to turn an absorbance reading (A280) into a protein concentration in µM and mg/mL.
Enter your values
Check these values
Your values are worked out in this browser. They are not sent to a server.
Your result will show here
Fill in the values, then choose Calculate.
Your result
How it was worked out
How to use this calculator
- Choose Extinction coefficient from a sequence and paste the protein sequence in one-letter or three-letter codes.
- Choose Calculate. You get two values: one with every pair of cysteines joined as a cystine, and one with all cysteines reduced. Use the one that matches your protein.
- If you already know the numbers of tryptophans, tyrosines and cystines, choose Extinction coefficient from counts instead.
- To find a concentration, choose Protein concentration from A280, then type the absorbance, the path length and, under More options, the dilution factor.
The method
At 280 nm a protein absorbs light mainly through tryptophan (W) and tyrosine (Y), and a little through cystines (pairs of cysteines joined by a disulfide bond). Pace, Vajdos, Fee, Grimsley and Gray (Protein Science, 1995) gave these values for proteins in water:
- ε280 = 5500 × number of W + 1490 × number of Y + 125 × number of cystines, in M⁻¹ cm⁻¹.
- Abs 0.1% = ε280 ÷ molecular mass in g/mol. It is the absorbance of a 1 mg/mL solution in a 1 cm cell.
- Concentration (Beer-Lambert law): c = A280 × dilution factor ÷ (ε280 × path length in cm), in mol/L. Mass concentration in mg/mL = c × molecular mass.
- The molecular mass is the average mass of the chain with free ends, from the standard atomic weights (CIAAW 2021). Each cystine takes away 2 hydrogen atoms.
Worked examples
From counts. Hen egg-white lysozyme has 6 tryptophans, 3 tyrosines and 4 disulfide bonds. ε280 = 5500 × 6 + 1490 × 3 + 125 × 4 = 37,970 M⁻¹ cm⁻¹. With a molecular mass of about 14,300 Da, Abs 0.1% = 37,970 ÷ 14,300 = 2.655.
Concentration. A280 = 0.65 in a 1 cm cell with ε280 = 37,970 M⁻¹ cm⁻¹ gives c = 0.65 ÷ 37,970 = 1.712 × 10⁻⁵ mol/L, which is 17.12 µM. With 14,300 Da that is 0.2448 mg/mL.
From a sequence. The made-up example MSWKTYCEGLWYRCDAHK has 2 W, 2 Y and 2 C. With the two cysteines as one cystine, ε280 = 11,000 + 2,980 + 125 = 14,105 M⁻¹ cm⁻¹. With them reduced, ε280 = 13,980 M⁻¹ cm⁻¹.
Limits you should know
- The values are predictions for a protein in water. The true coefficient of a folded protein can differ by a few percent, so measure it when you need high accuracy.
- Without tryptophan the prediction can be off by more than 10%. A protein with no W, Y or cystine has no predicted absorbance at 280 nm: use another method, such as a dye-binding assay.
- Read A280 against a blank of the buffer. Nucleic acids, particles that scatter light and other substances that absorb at 280 nm make the concentration too high. Readings above about 1.5 are often outside the straight-line range of the instrument.
- Only the 20 standard amino acids are read. Letters such as X or B stop the calculation with a message.
- For a general Beer-Lambert calculation of any substance use the Beer Lambert Calculator. For the mass of the chain use the Peptide Mass Calculator.