Works on this device
Heat Capacity Calculator
Heat capacity is the heat that warms a whole object by 1 kelvin (1 °C). Work it out from a measured heat and temperature change, from the mass and the material, or for a calorimeter in a lab.
Enter your values
Check these values
Your values are worked out in this browser. They are not sent to a server.
Your result will show here
Fill in the values, then choose Calculate.
Your result
How it was worked out
How to use this calculator
- Choose a task. The first one finds C from a heat and a change in temperature.
- Enter the values with their units. The change in temperature can be a start and end temperature, or a difference.
- Choose the unit of heat capacity you want: J/K, kJ/K, cal/K, kcal/K or BTU/°F.
- Choose Calculate. How it was worked out shows the formula with your numbers.
The formulas
- Heat capacity: C = Q ÷ ΔT. Turned round: Q = C × ΔT and ΔT = Q ÷ C.
- From the material: C = m × c, where c is the specific heat capacity of the material.
- Several parts: C = m1 × c1 + m2 × c2 + ... for a pot and the water in it, or any object made of parts.
- Molar heat capacity: Cm = c × M, where M is the molar mass in kg/mol. The heat capacity of n moles is n × Cm.
- Calorimeter: warm water (mass m_w, temperature T_w) is mixed with cold water (m_c, T_c) in the calorimeter, and the mixture ends at T_f. Then C_cal = (m_w × c × (T_w − T_f) − m_c × c × (T_f − T_c)) ÷ (T_f − T_c).
Heat capacity, specific heat and molar heat capacity
Heat capacity C (J/K) belongs to an object: a full kettle has a larger heat capacity than an empty one. Specific heat capacity c (J/(kg·K)) belongs to a material: it is the heat capacity of 1 kg. Molar heat capacity Cm (J/(mol·K)) is the heat capacity of 1 mole.
A kelvin and a Celsius degree are the same size, so J/K and J/°C are the same unit. A Fahrenheit degree is 5/9 of a kelvin, so 1 BTU/°F = 1,899.1 J/K.
Worked examples
41.86 kJ warms a body from 20 °C to 30 °C. C = 41,860 J ÷ 10 K = 4,186 J/K.
An aluminium pot of 0.5 kg (0.897 kJ/(kg·K)) holds 2 kg of water (4.186 kJ/(kg·K)). C = 0.5 × 897 + 2 × 4,186 = 448.5 + 8,372 = 8,820.5 J/K.
Calorimeter: 100 g of water at 60 °C is added to 100 g of water at 20 °C in the calorimeter, and the mixture ends at 38.5 °C. The warm water gave off 0.1 × 4,186 × 21.5 = 8,999.9 J; the cold water took in 0.1 × 4,186 × 18.5 = 7,744.1 J. C_cal = (8,999.9 − 7,744.1) ÷ 18.5 = 67.88 J/K.
Water, H2O, has M = 18.015 g/mol. With c = 4.186 kJ/(kg·K), Cm = 4,186 × 0.018015 = 75.41 J/(mol·K).
Limits you should know
- These formulas hold while nothing melts, freezes, boils or condenses. For a change of phase use the Latent Heat Calculator.
- Heat capacity changes with temperature. The material values in the menus are example values from common tables.
- The calorimeter method leaves out heat lost to the room, which makes the result a little high or low. For the heat of a reaction and other calorimetry, see the Calorimetry Calculator. For Q = m c ΔT of a material, use the Specific Heat Calculator.
- This page is about heat capacity in physics. For the cooling or heating capacity of an air conditioner or a furnace, use the Air Conditioner Size Calculator or the BTU Calculator.