Works on this device
Numerical Aperture Calculator
The numerical aperture (NA) tells how wide a cone of light a fibre, a lens or a microscope objective can take in. Find the NA and acceptance angle of an optical fibre, the NA of a lens, or the finest detail a microscope can show.
Enter your values
Check these values
Your values are worked out in this browser. They are not sent to a server.
Your result will show here
Fill in the values, then choose Calculate.
Your result
How it was worked out
How to use this calculator
- Choose a task: an optical fibre, the cladding or core index for an NA, a lens, or the resolution of a microscope.
- For a fibre, enter the refractive indices of the core and the cladding (or the core index and Δ). The medium outside is air unless you change it under More options.
- Choose Calculate. The working shows each step.
The formulas
- Definition: NA = n × sin θ, with θ the half-angle of the cone of light and n the index of the medium the cone is in.
- Optical fibre: NA = √(n₁² − n₂²), with the core index n₁ and the cladding index n₂. With Δ = (n₁² − n₂²) ÷ (2n₁²): NA = n₁ × √(2Δ).
- Acceptance angle: θa = arcsin(NA ÷ n₀), with n₀ the index outside (1 for air). The full cone is 2θa.
- Lens: θ = arctan(D ÷ (2f)) for a lens of diameter D at distance f; the working f-number is about 1 ÷ (2 × NA).
- Microscope resolution: Abbe d = λ ÷ (2 × NA); Rayleigh d = 0.61 × λ ÷ NA. With a condenser of its own NA: d = λ ÷ (NA_obj + NA_cond) and d = 1.22 λ ÷ (NA_obj + NA_cond).
Worked examples
A fibre. Core 1.48, cladding 1.46: NA = √(1.48² − 1.46²) = √0.0588 = 0.24249. In air the acceptance angle is arcsin(0.24249) = 14.033°, a cone of 28.067°. Δ = 1.3422%.
From Δ. Core 1.48 with Δ = 1%: NA = 1.48 × √0.02 = 0.20930, and the cladding index is 1.4651.
A lens. A lens 25 mm across with a focal length of 50 mm: θ = arctan(25 ÷ 100) = 14.036°, so NA = sin 14.036° = 0.24254 in air.
A microscope. An oil objective of NA 1.25 in green light (550 nm): Abbe d = 550 ÷ 2.5 = 220 nm; Rayleigh d = 0.61 × 550 ÷ 1.25 = 268.4 nm.
Limits you should know
- The fibre is a step-index fibre (one core index). For a graded-index fibre the NA is that of the centre of the core.
- The NA of a real fibre or lens may differ a little from the theoretical value. Use the data sheet when you have one.
- The resolution is the limit set by diffraction for a perfect objective. Aberrations, contrast and the camera often make it worse.
- For a round aperture such as a telescope or a camera lens see the Diffraction Limit Calculator. For more on microscopes see the Microscope Resolution Calculator. For the critical angle see the Critical Angle Calculator.