Works on this device
Concrete Shrinkage Calculator
Concrete shrinks as it dries and as the cement reacts. This page estimates the shrinkage strain of a member at an age by the model of Eurocode 2 (EN 1992-1-1), and how much a free member of a given length shortens.
Enter your values
Check these values
Your values are worked out in this browser. They are not sent to a server.
Your result will show here
Fill in the values, then choose Calculate.
Your result
How it was worked out
How to use this calculator
- Choose Shrinkage strain by Eurocode 2.
- Type the strength class fck (the box starts empty; Try an example fills in 30 MPa), choose the cement class and type the relative humidity of the air.
- Choose the shape of the member and type its size. The tool works out the notional size h0 = 2 Ac ÷ u.
- Type the age you want and the age at the end of curing. Under More options you can type a length to get the shortening.
- To turn a strain you already have into a length change, choose Length change for a strain.
The model (EN 1992-1-1:2004 3.1.4 and Annex B)
- Total: εcs = εcd + εca.
- Drying: εcd(t) = βds(t, ts) × kh × εcd,0, with βds = (t − ts) ÷ ((t − ts) + 0.04 √h0³) and h0 in mm.
- Basic drying strain: εcd,0 = 0.85 [(220 + 110 αds1) exp(−αds2 fcm ÷ 10)] × 10⁻⁶ × βRH, with βRH = 1.55 [1 − (RH ÷ 100)³], fcm = fck + 8 MPa, and αds1 = 3, 4, 6 and αds2 = 0.13, 0.12, 0.11 for cement class S, N and R.
- kh (Table 3.3): 1.0 for h0 = 100 mm, 0.85 for 200 mm, 0.75 for 300 mm and 0.70 for 500 mm or more.
- Autogenous: εca(t) = (1 − exp(−0.2 √t)) × 2.5 (fck − 10) × 10⁻⁶, with t in days.
- Length change: ΔL = ε × L.
Worked example
A slab 200 mm thick dries from both faces, so h0 = 200 mm and kh = 0.85. It is C30/37 (fck = 30 MPa, fcm = 38 MPa) with class N cement in air of 60% humidity, cured for 7 days.
βRH = 1.55 × (1 − 0.6³) = 1.215 and εcd,0 = 0.85 × 660 × exp(−0.456) × 1.215 × 10⁻⁶ = 432.1 × 10⁻⁶. At one year, βds = 358 ÷ (358 + 113.1) = 0.760, so εcd = 0.760 × 0.85 × 432.1 = 279.1 × 10⁻⁶. The autogenous part is 0.978 × 50 = 48.9 × 10⁻⁶, and the total 328.0 × 10⁻⁶. In the end the model gives 417.3 × 10⁻⁶.
A free slab 30 m long would shorten by 328.0 × 10⁻⁶ × 30 m = 9.8 mm in that year. A known strain of 400 × 10⁻⁶ on 30 m gives 12 mm.
Limits you should know
- This is one model with its own range: normal-weight concrete of C12/15 to C90/105. Eurocode 2 states that real shrinkage may differ by about 30 percent; tests of the mix give better values. Your National Annex may change parts of the model.
- It gives the strain of free concrete. A restrained member cracks or is stressed instead; joints and reinforcement are design questions.
- The ACI 209R model and other models are not built. For the water–cement ratio and strength, see the Concrete Water Cement Ratio Calculator and the Concrete Strength Estimator.
- The engineer of record and the code in force decide the design. It is not professional advice.