Works on this device
Concrete Water Cement Ratio Calculator
The water–cement ratio (w/c) is the weight of water in a concrete mix divided by the weight of cement. Less water for the same cement gives stronger, less permeable concrete. Use this page to work out the ratio, or the water or cement for a ratio.
Enter your values
Check these values
Your values are worked out in this browser. They are not sent to a server.
Your result will show here
Fill in the values, then choose Calculate.
Your result
How it was worked out
How to use this calculator
- Choose what you want to work out: the ratio, the water for a ratio, the cement for a ratio, w/cm with other cementitious materials, or Abrams' law.
- Type the water by volume (litres or gallons) or by weight, and the weight of cement. A litre of water is taken as 1 kg.
- To compare with the largest ratio your code allows for the exposure class, type it in the optional box. The tool holds no code limits.
- Choose Calculate.
The formulas
- w/c = weight of water ÷ weight of cement. c/w = 1 ÷ (w/c).
- Water = w/c × weight of cement. Cement = weight of water ÷ w/c.
- w/cm = weight of water ÷ (cement + fly ash + slag + silica fume + other cementitious materials).
- Abrams' law (1918): f = A ÷ B^(w/c), and so w/c = ln(A ÷ f) ÷ ln B, with A and B fitted to your own materials.
Worked examples
A batch has 180 litres of water and 360 kg of cement: w/c = 180 ÷ 360 = 0.50, and c/w = 2.0.
For w/c = 0.45 and two 50 kg bags of cement, the water is 0.45 × 100 = 45 litres, or 22.5 litres for each bag.
With 90 kg of fly ash added to the same batch, w/cm = 180 ÷ (360 + 90) = 0.40, while w/c for the cement alone stays 0.50.
With example constants A = 96.5 MPa and B = 7, Abrams' law gives 96.5 ÷ 7^0.5 = 36.5 MPa at w/c = 0.5, and w/c = 0.521 for 35 MPa. These constants are for trying the tool only.
Limits you should know
- The largest w/c or w/cm for an exposure class, and the strength that goes with it, come from the code in force (for example ACI 318-19 Table 19.3.2.1, EN 206 Annex F or IS 456 Table 5). The tool holds none of them.
- The ratio counts free water. Water held inside the aggregate is not part of it, and free water on wet aggregate is.
- Abrams' law needs constants for your own cement, aggregate, age and test. The EN 206 k-value method for additions is not worked out.
- For cement, sand and stone quantities, use the Concrete Quantity Calculator. For strength with age, see the Concrete Strength Estimator.
- It is not professional advice. A structural mix follows a mix design and trial batches.