Toolvito

Works on this device

Footing Area Calculator

Find how large a footing must be so that the pressure on the soil stays within the allowable bearing pressure. Type the load and the bearing pressure from your soil report or building code, and choose the shape.

Enter your values

The plan area and the sides of a footing so that the soil pressure stays within the allowable bearing pressure you type.

Your values

The service load from the column, post or pier above: dead load plus live load, without load factors.

From your soil report, or the presumptive values of the building code in force (for example IRC Table R401.4.1). The example is not a value for any site.

The footing and the soil on top of it press on the ground too, so they use up part of the bearing pressure.

From the finished ground down to the underside of the footing. The soil above the footing fills the rest of this depth.

More options

Reinforced concrete is often taken as 24 to 25 kN/m³ (about 150 lbf/ft³). Use the value your engineer uses.

18 kN/m³ (about 115 lbf/ft³) is an example only. Use the value from your soil report.

For example 0.05 m (50 mm) or 3 in. Leave it empty to see the exact size only.

Your values are worked out in this browser. They are not sent to a server.

Your result will show here

Fill in the values, then choose Calculate.

How to use this calculator

  1. Choose Footing size for a load, then the shape: a square pad, a rectangle, a round pad under a pier, or a strip under a wall.
  2. Type the service load from above and the allowable bearing pressure (qa). The bearing pressure box starts empty: take the value from your soil report or your building code. Try an example fills in example values.
  3. Keep add it to count the weight of the footing and the soil on top of it, and type the thickness of the footing and the depth of its base.
  4. Under More options you can change the unit weights and the step that each side is rounded up to.
  5. Choose Calculate. To check a footing you already have, choose Load a footing of a given size can carry.

The formulas

  • Footing and soil: q_sw = γc × t + γs × (Df − t), where t is the thickness of the footing and Df the depth of its base below the ground.
  • Net pressure for the load: q_net = qa − q_sw.
  • Area: A = P ÷ q_net. A square has the side √A, a round pad the diameter √(4A ÷ π), and a rectangle B = √(A ÷ ratio) and L = ratio × B.
  • Strip footing: width B = w ÷ q_net, with w the load on each metre (or foot) of the wall.
  • Load a footing can carry: P = q_net × A.

Worked example

A column brings 500 kN. The soil report gives an allowable bearing pressure of 200 kPa. The footing is 0.5 m thick with its base 1 m below the ground, concrete 24 kN/m³ and soil 18 kN/m³.

q_sw = 24 × 0.5 + 18 × 0.5 = 21 kPa, so q_net = 200 − 21 = 179 kPa. A = 500 ÷ 179 = 2.793 m², and a square footing needs a side of √2.793 = 1.671 m. Rounded up to 1.70 m, the area is 2.89 m² and the pressure under the footing is 500 ÷ 2.89 + 21 = 194.0 kPa, below 200 kPa. The footing holds 1.445 m³ of concrete.

The other way round: a square footing of 1.8 m on the same soil can carry (200 − 21) × 3.24 = 580.0 kN.

Limits you should know

  • The allowable bearing pressure must come from a soil report or from the building code in force where you build. The tool holds no such value, and the example is not a value for any site.
  • The load is taken at the centre of the footing, so the pressure is even. For a moment or an off-centre load, use the Foundation Pressure Calculator. For the bearing capacity of the soil itself, see the Soil Bearing Capacity Calculator.
  • Use service loads (dead plus live load without load factors) with an allowable bearing pressure.
  • The tool does not check settlement, frost depth, or the bending, shear and punching strength of the footing. For the concrete and its cost, use the Concrete Quantity Calculator; for the bars, the Slab Reinforcement Estimator.
  • This is arithmetic for the values you type. A qualified engineer and the building code in force decide the size of a real footing. It is not professional advice.