Works on this device
Foundation Pressure Calculator
Find the pressure that a footing puts on the soil. Type the load and the size of the footing, and a moment if the load is not at the centre. The tool shows the highest and lowest pressure and the part of the base that stays in contact.
Enter your values
Check these values
Your values are worked out in this browser. They are not sent to a server.
Your result will show here
Fill in the values, then choose Calculate.
Your result
How it was worked out
How to use this calculator
- Choose a calculation: a load at the centre, a moment along one side, or moments along both sides.
- Type the size of the footing and the service load on it. For a moment, type the moment or the eccentricity (how far the load is from the centre).
- Choose add it to count the weight of the footing and the soil on top of it.
- Type an allowable bearing pressure if you want to compare with it. That box starts empty: the value comes from your soil report or building code.
- Choose Calculate. With one moment, the table and the chart show the pressure across the base.
The formulas
- Centred load: q = P ÷ A + q_sw, where q_sw = γc × t + γs × (Df − t) is the weight of the footing and the soil on it for each unit of area.
- Moment along B (rectangle B × L): e = M ÷ (P + W). While e ≤ B ÷ 6 (inside the kern), q = (P + W) ÷ (B L) × (1 ± 6 e ÷ B). This is the same as P ÷ A ± M ÷ S, with S = L B² ÷ 6.
- Outside the kern (B ÷ 6 < e < B ÷ 2): the soil cannot pull on the footing. The pressure is a triangle on the contact length 3 × (B ÷ 2 − e), and q_max = 2 (P + W) ÷ (3 L (B ÷ 2 − e)).
- Moments along both sides: q = (P + W) ÷ (B L) × (1 ± 6 eB ÷ B ± 6 eL ÷ L) at the corners, while 6 eB ÷ B + 6 eL ÷ L ≤ 1.
Worked example
A footing 2 m by 2.5 m carries 800 kN and a moment of 200 kN·m along the 2 m side. The eccentricity is e = 200 ÷ 800 = 0.25 m, inside the kern limit 2 ÷ 6 = 0.333 m. The mean pressure is 800 ÷ 5 = 160 kPa, and 6e ÷ B = 0.75, so q_max = 160 × 1.75 = 280 kPa and q_min = 160 × 0.25 = 40 kPa.
With a moment of 400 kN·m, e = 0.5 m is outside the kern. Only 3 × (1 − 0.5) = 1.5 m of the 2 m base presses on the soil, and q_max = 2 × 800 ÷ (3 × 2.5 × 0.5) = 426.7 kPa.
With moments of 120 kN·m along B and 80 kN·m along L, eB = 0.15 m and eL = 0.1 m, the kern check is 0.45 + 0.24 = 0.69, and the corners carry 270.4, 193.6, 126.4 and 49.6 kPa.
Limits you should know
- The footing is taken as rigid, so the pressure changes in a straight line across the base. This is the usual hand method.
- With moments along both sides, the tool gives the corner pressures only while the whole base stays in contact. Beyond that it says so and gives no corner values.
- Round footings are covered for a centred load only. Sliding, overturning safety and settlement are not checked.
- The allowable bearing pressure comes from a soil report or the building code in force. To size a footing for a load, use the Footing Area Calculator; for the bearing capacity of the soil, the Soil Bearing Capacity Calculator.
- This is arithmetic for the values you type. A qualified engineer and the building code in force decide the design of a real foundation. It is not professional advice.