Toolvito

Works on this device

Earth Pressure Calculator

Find the sideways pressure of soil on a retaining wall and the force it makes, with a load on the ground and a water table if you have them. Get the earth pressure coefficients by Jaky, Rankine and Coulomb, and the thrust in an earthquake by Mononobe-Okabe.

Enter your values

The lateral earth pressure down a wall with a vertical back and level ground, and the resultant force for each metre or foot of wall with its height above the base.

Your values

The effective angle of shearing resistance, from tests or the geotechnical report. 30° is an example.

Above the water table. 18 kN/m³ is an example; take the value for your soil.

Leave it empty for sand and gravel. Many designs leave cohesion out of the active pressure on a wall.

Such as traffic or stored material spread over the whole ground behind the wall.

Leave it empty when the soil behind the wall is drained.

Your values are worked out in this browser. They are not sent to a server.

Your result will show here

Fill in the values, then choose Calculate.

How to use this calculator

  1. Choose what you want to work out. Pressure and force on a wall is the usual case.
  2. Choose active, at rest or passive pressure, and type the friction angle φ′ of the soil, its unit weight and the height of the wall.
  3. Add a cohesion, a load on the ground (surcharge) and the depth of the water table if they apply.
  4. For wall friction, a sloping back or sloping ground, use the Coulomb calculation. For an earthquake, type the seismic coefficients of your code in the Mononobe-Okabe calculation; those boxes start empty.
  5. Choose Calculate. The table and the chart show the pressure down the wall.

The formulas

  • At rest (Jaky): K0 = 1 − sin φ′.
  • Rankine: Ka = (1 − sin φ′) ÷ (1 + sin φ′) = tan²(45° − φ′ ÷ 2), Kp = 1 ÷ Ka, for a smooth vertical wall and level ground.
  • Pressure: σh′ = K × σv′ − 2c′ × √K (active, never below 0) or K × σv′ + 2c′ × √K (passive), with σv′ = q + γ × z, and γsat − γw below the water table. The water pressure γw × (z − zw) is added in full.
  • Force: the area of the pressure diagram, P = ½ × K × γ × H² for a dry soil without load, acting at H ÷ 3 above the base.
  • Coulomb: Ka = cos²(φ′ − θ) ÷ [cos²θ × cos(δ + θ) × (1 + √(sin(φ′ + δ) × sin(φ′ − α) ÷ (cos(δ + θ) × cos(θ − α))))²].
  • Mononobe-Okabe: the same form with ψ = arctan(kh ÷ (1 − kv)) added, and PAE = ½ × γ × H² × (1 − kv) × KAE.

Worked examples

A wall 5 m high holds back dry sand with φ′ = 30° and γ = 18 kN/m³. Ka = 1/3, so the pressure at the base is 18 × 5 ÷ 3 = 30 kPa and the force is ½ × 30 × 5 = 75 kN for each metre of wall, at 1.667 m above the base. At rest, K0 = 0.5 and the force is 112.5 kN/m.

A load of 10 kPa on the ground adds 10 ÷ 3 = 3.33 kPa down the whole wall, so 16.67 kN/m more. The total is 91.67 kN/m at 1.818 m above the base.

With wall friction δ = 20°, Coulomb gives Ka = 0.2973 and a thrust of 66.9 kN/m. With δ = 15° and an example kh = 0.2, Mononobe-Okabe gives KAE = 0.4520 and PAE = 101.7 kN/m, against 67.8 kN/m without the earthquake.

Limits you should know

  • Soil strength, wall friction, the seismic coefficients and the safety factors come from the geotechnical report and the code in force where the wall is built. That code decides; this tool does not give the required values.
  • Active pressure needs the wall to move a little away from the soil, and full passive pressure needs a large movement. A wall that cannot move takes the at-rest pressure.
  • Rankine takes a smooth vertical wall and level ground. Coulomb here is for a dry backfill without cohesion. Passive pressure by Coulomb with wall friction is left out, because it gives too high a value when δ is large.
  • Line loads, strip loads and compaction pressures are not covered. The bearing pressure under the footing of the wall is on the Soil Bearing Capacity Calculator, and the density of the soil on the Soil Density Calculator.
  • This is arithmetic for the values you type. A retaining wall must be designed and checked by a qualified engineer. It is not professional advice.