Works on this device
Soil Bearing Capacity Calculator
Estimate the pressure a shallow footing can put on the soil before the soil fails in shear, by Terzaghi's bearing capacity equation. Type the size of the footing, its depth and the strength of the soil from your site investigation.
Enter your values
Check these values
Your values are worked out in this browser. They are not sent to a server.
Your result will show here
Fill in the values, then choose Calculate.
Your result
How it was worked out
How to use this calculator
- Choose the shape of the footing: a long strip, a square or a circle. Type its width (or diameter) and the depth of its base below the ground.
- Type the unit weight of the soil above and below the base, and the cohesion c and friction angle φ of the soil below it. These come from a site investigation.
- Type a factor of safety if you want the allowable value. Leave it empty for the ultimate value only.
- Under More options you can choose local shear failure for loose or soft soil, and the formula for Nγ.
- Choose Calculate. The working shows each factor and each part of the equation.
The equation
q_ult = c × Nc × sc + q × Nq + 0.5 × γ × B × Nγ × sγ, where q = γ × Df is the pressure of the soil at the level of the base.
Terzaghi's shape factors: a strip has sc = 1 and sγ = 1, a square sc = 1.3 and sγ = 0.8, a circle sc = 1.3 and sγ = 0.6 (so the last part is 0.4 γ B Nγ for a square and 0.3 γ B Nγ for a circle).
- Nq = e^(π tan φ) × tan²(45° + φ ÷ 2) (Prandtl and Reissner).
- Nc = (Nq − 1) × cot φ; at φ = 0 it is π + 2 = 5.14.
- Nγ by one of three published formulas: Vesic (1973) 2 (Nq + 1) tan φ, Meyerhof (1963) (Nq − 1) tan(1.4 φ), or Brinch Hansen (1970) 1.5 (Nq − 1) tan φ.
- Local shear (Terzaghi): use 2c ÷ 3 and an angle whose tangent is 2 tan φ ÷ 3.
- Allowable = q_ult ÷ FS. Net allowable = (q_ult − q) ÷ FS. Some codes call net allowable + q the safe bearing capacity.
Worked example
A strip footing 1.5 m wide sits 1 m deep in soil of 18 kN/m³ with c = 10 kPa and φ = 30°. Then Nq = 18.40, Nc = 30.14 and Nγ (Vesic) = 22.40. The overburden is q = 18 × 1 = 18 kPa.
q_ult = 10 × 30.14 + 18 × 18.40 + 0.5 × 18 × 1.5 × 22.40 = 301.4 + 331.2 + 302.4 = 935.1 kPa. With a factor of safety of 3, the allowable pressure is 311.7 kPa, about 467.5 kN for each metre of the wall.
The same soil under a 1.5 m square footing gives q_ult = 965.0 kPa and an allowable 321.7 kPa, or 723.7 kN on the footing.
Limits you should know
- This is a textbook estimate. A site investigation and a qualified geotechnical engineer decide the bearing capacity of a real foundation, which must follow your local building code. It is not professional advice.
- The tool holds no soil values, no factor of safety and no code limits. The starting values are examples only.
- The equation is for a shallow footing (depth not more than its width) on one uniform soil, with a vertical load at its centre and level ground. It does not check settlement, which often limits the allowable pressure more than shear does.
- Results from SPT blow counts, plate load tests and piles need other, often empirical, methods and are not given here.
- For the pressure a given load puts under a footing, and the size of a footing for a load, see the Foundation Pressure Calculator and the Footing Area Calculator.