Toolvito

Works on this device

Connection Eccentricity Calculator

Work out the force on each bolt of a bolt group when the load does not pass through its centre, such as a bracket on a column flange. Type the bolt positions and the load; the page uses the elastic method and finds the critical bolt.

Enter your values

Your values

A load that pushes down is negative, such as −100.

In the same axes as the bolts. For a vertical load, the x of its line.

For a horizontal load, the y of its line.

The design or allowable shear strength of one bolt from your code (single or double shear as built). Not built in.

Bolt positions

This unit is used in every row.

Your values are worked out in this browser. They are not sent to a server.

Your result will show here

Fill in the values, then choose Calculate.

How to use this calculator

  1. Type the position x, y of every bolt in one unit. Any origin will do: the page finds the centre of the group.
  2. Type the load across and up (a load pushing down is negative), and a point on its line in the same axes.
  3. Type the shear strength of one bolt from your code if you want to compare. Choose Calculate.
  4. The table shows the force on each bolt; the result names the critical bolt and the coefficient C.

The elastic method

  • Centre of the group: x̄ = Σx ÷ n and ȳ = Σy ÷ n. Each bolt is at x' = x − x̄, y' = y − ȳ from it.
  • Polar moment of the group: Ip = Σ(x'² + y'²), for bolts of one size.
  • Moment: M = (x_P − x̄) × P_y − (y_P − ȳ) × P_x, anticlockwise positive, for a load (P_x, P_y) whose line passes through (x_P, y_P).
  • Force on a bolt: R_x = P_x ÷ n − M × y' ÷ Ip and R_y = P_y ÷ n + M × x' ÷ Ip; R = √(R_x² + R_y²). The largest R is the critical bolt.
  • Coefficient C = P ÷ R_max: the group carries C × R_v, with R_v the strength of one bolt.

Worked example

Six bolts in two rows 75 mm apart and three rows 75 mm apart (at x = 0 and 75 mm, y = 0, 75 and 150 mm) carry 100 kN down on a line 250 mm from the left bolts. The centre is at (37.5, 75) mm, so the eccentricity is 212.5 mm and M = −21.25 kN·m (clockwise).

Ip = 6 × 37.5² + 4 × 75² = 30,937.5 mm². Each bolt takes 100 ÷ 6 = 16.67 kN down. The bolts at (75, 0) and (75, 150) also take 21,250 × 75 ÷ 30,937.5 = 51.52 kN across and 21,250 × 37.5 ÷ 30,937.5 = 25.76 kN down, so R_max = √(51.52² + 42.42²) = 66.74 kN and C = 100 ÷ 66.74 = 1.498.

Limits you should know

  • The elastic method takes every bolt as the same size and equally stiff, with the plate turning about the centre of the group. It is simple and cautious; the instantaneous centre of rotation method of steel codes usually gives a higher capacity and is not worked out here.
  • Only loads in the plane of the bolt group are covered. Bolts in tension (a load out of the plane), bearing on the plates, edge distances and the plates are not checked.
  • For a load through the centre of the group, and for bearing and group capacity, use the Bolted Connection Calculator.
  • This is arithmetic for study and checking. It does not check a design: the engineer of record and the code in force decide. It is not professional advice.

Related tools