Toolvito

Works on this device

Anchor Bolt Calculator

Work out the loads on anchor bolts and the arithmetic around them. Share the uplift, moments and shear between the anchors of a group, check tension and shear together against the capacities of your code, find the pull-out by bond or the embedment it needs, and add up the length of a bolt.

Enter your values

The share of the uplift, the moments and the shear that each anchor takes, for a rigid plate with every anchor in tension.

Your values

The uplift on the plate, at the centre of the anchors. Type 0 if there is none.

A positive Mx pulls harder on the anchors with a positive y.

A positive My pulls harder on the anchors with a positive x.

The stress your code allows on the tensile stress area of the anchor, with its factors. Not built in.

Anchor positions

This unit is used in every row.

Your values are worked out in this browser. They are not sent to a server.

Your result will show here

Fill in the values, then choose Calculate.

How to use this calculator

  1. Choose a calculation: the loads on each anchor, the interaction check, pull-out by bond, or the total length.
  2. For the loads, type the position of each anchor and the uplift, shear and moments on the plate.
  3. For the checks, type the capacities from your code check or the anchor maker, and the exponent your code uses. Nothing is built in.
  4. Choose Calculate. Each result says what it covers and what it leaves out.

The formulas

  • Tension on each anchor (rigid plate, every anchor in tension): T = N ÷ n + Mx × y' ÷ Σy'² + My × x' ÷ Σx'², with x' and y' measured from the centre of the anchors. Shear: V ÷ n on each anchor.
  • Interaction of tension and shear: (N ÷ N_cap)^ζ + (V ÷ V_cap)^ζ ≤ 1. ζ = 1 is a straight line; some codes allow a power such as 5/3.
  • Pull-out by bond: N = π × d × h × τ, with d the diameter, h the embedment depth and τ the bond strength. Embedment for a load: h = N ÷ (π × d × τ).
  • Bolt length: embedment + grout + plate + washers + nuts + thread past the nut (+ a hook for an L or J bolt).

Worked example

Four anchors at ±150 mm carry an uplift of 40 kN and a moment Mx of 6 kN·m. Σy'² = 4 × 150² = 90,000 mm². The top anchors take 40 ÷ 4 + 6,000,000 × 150 ÷ 90,000 = 10 + 10 = 20 kN and the bottom ones 10 − 10 = 0 kN. With 20 kN of shear, each anchor takes 5 kN.

With N = 15 kN against a capacity of 30 kN, V = 5 kN against 20 kN and ζ = 5/3: 0.5^(5/3) + 0.25^(5/3) = 0.315 + 0.099 = 0.414, so the check passes.

A 16 mm bar 125 mm deep with τ = 8 MPa gives π × 16 × 125 × 8 = 50.27 kN by bond; for 40 kN it needs 40,000 ÷ (π × 16 × 8) = 99.47 mm. A bolt with 300 mm embedment, 25 mm grout, a 20 mm plate, an 8 mm washer, a 16 mm nut and 10 mm of thread past it is 379 mm long. The capacities and bond strength are examples for trying the tool, not values for a product.

Limits you should know

  • The concrete breakout, pull-out, side-face blowout and pryout rules of ACI 318 chapter 17 or EN 1992-4 are not computed. Every capacity, bond strength and embedment depth is the figure that you type, from your code check or the anchor maker (for example their design software and approvals).
  • The share of the loads takes a rigid plate and every anchor in tension. When part of the plate presses on the concrete, the page stops and says so. For the pressure under a plate, see the Base Plate Calculator.
  • For the weight of anchor bolts, use the Fastener Weight Calculator. For the steel of a bolt in tension, the Bolt Tensile Calculator. For bolts between steel plates, the Bolted Connection Calculator.
  • This is arithmetic for study and checking. It does not check a design: the engineer of record and the code in force decide. It is not professional advice.

Related tools